Programming; Configuration Menu - Varian Turbo-V 81-AG Rack Controller Notice De Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 13
Pressing the COUNTERS key, the following is
obtained:
C Y C L E
T
I M E
LS
AG
VACUUM TECHNOLOGIES
COUNTERS
increase
decrease
LOW SPEED
Turbo-V 81-AG
Where
CYCLE XXXX
TIME
XXXXXm
Pressing again:
P U M P
X X X X X X h
Where:
PUMP LIFE
XXXXXX total operating time (hours)of the
pump
X X X X
X X X X X m
R1
R2
MEASURES
next
menu
previous
START/STOP
Number of start/stop cycles
Time of last cycle (minutes)
L
I
F E

Programming

Configuration menu

To
access
the
COUNTERS + MEASURES buttons at the same time
for at least 2 sec.
LS
AG
COUNTERS
increase
decrease
LOW SPEED
In programming mode, the meaning of the 4 buttons
changes as follows:
COUNTERS/LOW SPEED become "INCREASE
and DECREASE" and make it possible to select the
next or previous value of a parameter (in the case
of compulsory parameters) or to increase/decrease
the individual digit of a parameter (in the case of
numeric parameters)
The "MEASURES and START/STOP" buttons
become "NEXT and PREVIOUS" and make it
possible to select the next parameter (or next digit
of a numeric parameter) or previous parameter.
Switching from one parameter to the next (using the
"NEXT" key) indicates confirmation of any changes
made to the specific parameter. If the changes cannot
be accepted by the controller, the " Data out of limits "
error message is displayed, the changes are cancelled
and the value of the parameter prior to the modification
is reproposed.
91
TECHNICAL INFORMATION
configuration
menu,
press
R1
R2
VACUUM TECHNOLOGIES
MEASURES
next
menu
previous
START/STOP
Turbo-V 81-AG
87-900-986-01 (C)
the

Publicité