5. MEMORIZATION PROCEDURE
WARNING: After powering the control panel, wait 2 seconds before you start performing the
adjustment operations.
Note: The gate must be equipped with the opening and closing safety stops.
When you have completed the installation procedures :
1_ bring the gate to approx. 1 m from the closing travel limit;
2_ set dip-switch no. 10 to ON;
3_ operate the automation using one of the following inputs: A/C, radio control or card button (O/C);
4_ the gate must start to close.
STOP pushbutton input (Normally Closed contact); It stops the gate
in any position, temporarily inhibiting its automatic closing, if pro-
grammed. 4= COMMON, 5= STOP.
NOTE: A safety micro-switch is connected to the STOP push-
button. In case the STOP input remains open for more than
5 seconds, the operator will perform a cycle at a slow speed
to reset the operating parameters to the values originally
saved (see "Restoring automatic operation"). The micro-switch
should be connected in series to further STOP push-buttons
where present.
OPEN/CLOSE pushbutton input (Normally Open contact); It com-
mands the opening and closing of the gate and its operation is con-
trolled by dip-switches 2 and 4. 5= OPEN/CLOSE.
PEDESTRIAN pushbutton input (Normally Open contact); It com-
mands the partial opening and closing of the gate for ~1 m of travel
and its operation is controlled by dip-switches 2 and 4. 7= PEDESTRIAN.
24 V DC, max. 15 W, output to POWER THE RXs AND ANY OTHER
TXs OF PHOTOCELLS THAT ARE PRESENT, EXTERNAL RECEIVERS, etc.;
connect a max. of 3 pair of photocells. 8= NEGATIVE, 9= POSITIVE.
24 V DC, output for PHOTOCELL TX (only the one that performs the
Phototest) max. no. 1 photocell transmitter.
10= NEGATIVE, 11= POSITIVE.
FLASHING LIGHT output 24 V DC, max. 20 W. The signal is already
modulated for direct use. Flashing frequency during closing is dou-
ble. 12= NEGATIVE, 13= POSITIVE.
GATE OPEN LED output 24 V DC, max. 3 W; during opening of the
gate the warning light flashes slowly, when the gate is open it re-
mains steadily illuminated and during closure it flashes twice as
fast. 14= NEGATIVE, 15= POSITIVE.
2
RADIO CHANNEL output (its operation depends on dip-switches
nd
nos. 7 - 8) to be used for opening/closing another gate, for control-
ling garden lights or for the "ZONE LIGHTING" function.
Warning: to connect other devices to the 2nd Radio Channel
(area lighting, pumps, etc.), use an additional auxiliary relay.
433,92 MHz built-in RX ANTENNA input.
18= EARTH, 19= SIGNAL.
quick coupling for ENCODER connection.
White= 0 V DC (GND), brown= 5 V DC (+5V),
green= ENCODER SIGNAL (ENC).
encoder supply and input
20 white= 0 V DC (GND), 21 brown= 5 V DC (+5V),
22 green= ENCODER SIGNAL (ENC).
Starting from 30th June 2017, the encoder's
connections are the following: 20 green = 0 V DC (GND),
21 brown = 5V DC (+5V), 22 white = Encoder signal (ENC)
MOTOR supply output 24 V DC, max. 50 W.
23= NEGATIVE, 24= POSITIVE.
quick coupling for BATTERIES 19,2 V DC - 1,2 Ah connection.