AVENTICS | AS1 / AS2 / AS3 / AS5 | R412013437–BAL–001–AH | English
6

Service and Repairs

Cleaning and servicing
W
Close all openings with suitable safety devices so that
no cleaning agent can enter into the system.
W
Never use aggressive solvents or detergents. Only
clean the product using a slightly damp cloth. Only use
water and, if necessary, a mild detergent.
W
Do not use high-pressure cleaners for cleaning.
W
Do not use compressed air for cleaning (blowing off)
the maintenance unit or equipment.
7
Decommissioning,
Disassembly, Replacement
Danger of injury in case of disassembly
or replacement under pressure or voltage
Disassembling or replacement when under pressure
or electrical voltage may lead to injuries and damage
to the product or system components.
O Make sure that the relevant system part is not under
voltage or pressure before you assemble the
product or replace parts.
O Protect the system against being switched on.
Replace sensor for electrical
6
level detection (AS2/3/5 only)
Please only use a ST6 sensor with reed contact
for electrical level detection.
1. Release the fastening screw on sensor ST6 (c).
2. Lift out the old sensor ST6 (c) from the bracket (a).
3. Push down the new ST6 sensor (c) into the bracket (a)
as far as it will go (b).
4. Tighten the fastening screw slightly.
8
Disposal
Dispose of the product and condensate in accordance
with the national regulations in your country.
CAUTION
9
Troubleshooting
Malfunction
Possible cause
Oil content of
Oil has fallen
compressed air
below minimum
too low
filling level in the
reservoir
Dosage is too low Increase no. of
Ambient
temperature is
lower than at
time of
adjustment
Oil content of
Oil has been
compressed air
filled
too high
to over the max.
filling level in the
reservoir
Dosage is too
high
Ambient
temperature is
higher than at
time of
adjustment

10 Technical Data

Maximum permissible pressure, temperature range,
and thread connection are indicated on the products.
General data
Mounting orientation
Vertical
Medium/ambient
-10 °C /+50 °C
temperature
min./max.
Further technical data can be found in our
online catalog at
www.aventics.com/pneumatics-catalog.
8
Remedy
Top up oil in the
reservoir
drops
Please use oil
with a lower
viscosity level
Empty oil to the
max. filling level
in the reservoir
Reduce no. of
drops
Please use oil
with a higher
viscosity level