W AteR ConneCtIon.
5
1
Draining
A water drain (1) with siphon must be installed in the vicinity of the machine.
Remove the drip tray (2) complete with grille.
Connect the drain tube (3) provided to the union (4) of the machine and the
other end to the previously prepared drain siphon (5), checking that the drain
tube runs freely without constrictions or obstructions.
2
7
filling
6
Connect the filling tube (6) provided to the union (7) of the machine and the
other end to a softener (8).
3
W ARNING: The machine connection operations must be carried out
by a specialised and authorised technician.
W ARNING: The drain siphon must be positioned at least 20cm below
the machine support surface.
CAUTION: The machine must absolutely be connected to a water
mains supplying drinking water appropriately softened to a
maximum hardness of 3.5/5 french degrees (60/85 ppm).
Check that the supply pressure does not exceed 2 bar (0.2 MPa). If
the pressure is greater, install a pressure reducer.
W ARNING: The water supply system should have a shut-off tap (9)
located upstream of the softener to separate the water system from
the machine.