TROUBLE SHOOTING
MODEL: RAS-18SX8
Inspection instructions
Warning
Note that the 0 V line of the
outdoor electrical installation
and the primary power
circuit of the indoor
electrical installation have
voltages to ground as
illustrated in the right-hand
figure.
Warning
When conducting a check
with an oscilloscope or
something similar, do not
ground the oscilloscope.
Note that the oscilloscope
will be subjected to voltages
as illustrated in the figure
above.
Downloaded from
www.Manualslib.com
Two-way valve coil
Indoor electrical installation
Power supply
A
B
Grounding
Grounding voltage
manuals search engine
Indoor fan motor
M
a
b
Control circuit
Voltage between each
part and ground
Do not under any
circumstances get your
hand or metal part into
contact with the cabinet.
– 214 –
Outdoor electrical installation
c
OV line
d
Control circuit
Potential at points
a
c
310 V−324 V
310 V−324 V
Potential
b
d
at points
Danger!!!
Do not install
a grounding.
Compressor
motor
M