MODE D'ECLAIRAGE DU VOYANT D'AUTO-DIAGNOSTIC
MODÈLE RAC-25WX8, RAC-35WX8
IPM
BLOC D'ALIMEN-
TATION INTELLIGENT
LAMPES AUTO-DIAGNOSTIC
Downloaded from
www.Manualslib.com
COUPEZ L'ALIMENTATION
ÉLECTRIQUE ET ATTENDEZ
PLUS DE 10 MINUTES
AVANT D'EFFECTUER LE
TRAVAIL DE MAINTENANCE
VÉRIFIEZ LA TENSION CC
AU POINT DE MESURE
INDIQUÉ SUR LA FIGURE:
IL DOIT ÊTRE INFÉRIEUR À
10 V
NE TOUCHEZ PAS AUX
AUTRES COMPOSANTS
LORSQUE VOUS UTILISEZ
LE COMMUTATEUR DE
MAINTENANCE
OPÉRATION DE MAINTENANCE
PROCÉDURE DE RÉFRIGÉRATION, POMPE
ARRÊTÉE OU OPÉRATION INDÉPENDANTE DE
L'UNITÉ EXTÉRIEURE
1. METTEZ L'APPAREIL HORS TENSION ET
REMETTEZ-LE SOUS TENSION.
2. ATTENDEZ AU MOINS 1 MINUTE.
3. APPUYEZ SUR LE COMMUTATEUR DE
MAINTENANCE (SUR LE C.I.) PENDANT
PLUS DE 1 SECONDE.
L'OPÉRATION DE MAINTENANCE DÉMARRE.
POUR ARRÊTER CETTE OPÉRATION, APPUYEZ
À NOUVEAU SUR LE COMMUTATEUR DE
MAINTENANCE (PENDANT PLUS DE 1
SECONDE).
POUR RELANCER LE FONCTIONNEMENT
NORMAL, COUPEZ ET RALLUMEZ À NOUVEAU
LA SOURCE D'ALIMENTATION.
AFIN DE PROTÉGER LE COMPRESSEUR
D'ÉVENTUELS DOMMAGES, NE PAS FAIRE
FONCTIONNER L'APPAREIL PENDANT PLUS DE
5 MINUTES AVEC LA VANNE DE MAINTENANCE
FERMÉE.
manuals search engine
: ALLUMÉ
MODE D'ALLUMAGE AUTO-DIAGNOSTIC
POI N T DE CONTRÔLE
NOM AUTO-
D É T A I L S
DIAGNOSTIC
PRI N CI P AL
PENDANT LE FONCTI O NNEMENT
LD303 (ROUGE) S' A LLUME
FONCTIONNEMENT
FONCTIONNEMENT
NORMAL
COMPRESSEUR
VALEUR
SURCHARGE
RÉGLÉE
DURÉE
SURCHARGE
INDIQUE UN ÉTAT DE PROTECTION
LA VITESSE DE ROTATION EST
DE SURCHARGE
CONTRÔLÉE AUTOMATIQUEMENT
POUR PROTÉGER LE
SURCHARGE
PAS UN DYSFONCTIONNEMENT
COMPRESSEUR EN CAS DE
SURCHARGE
PENDANT L'ARRÊT
LD303 (ROUGE) S'ÉTEINT
ARRÊTÉ PAR LE THERMOSTAT
ARRÊT NORMAL
PAS UN DYSFONCTIONNEMENT
OU LE CONTRÔLEUR
RÉINIT. DU MICROPROCESSEUR
ARRÊT
(NORMAL QUAND LE COMMUT.
RÉINIT.
1 FOIS
M/A A ÉTÉ MIS SUR MARCHE)
COUPURE
LE COURANT DE CRÊTE DU
COURANT DE
COMPRESSEUR A DÉPASSÉ LA
CRÊTE
2 FOIS
LIMITE MAXIMUM
ROTATION
POSITION DU ROTOR DE
BASSE VITESSE
COMPRESSEUR PERDUE
3 FOIS
ANORMALE
ÉCHEC DE COMMUTATION DE
ÉCHEC DE
DÉMARRAGE SYNC. BASSE FRÉQUENCE
COMMUTATION
4 FOIS
SUR POSITION DE DÉTECTION
L'UNITÉ EXTÉRIEURE EST EXPOSÉE À LA LUMIÈRE
COUPURE LIMITE
FONCTION DE PROTECTION ANTI-SURCHARGE
DIRECTE DU SOLEIL OU SON FLUX D'AIR EST BLOQUÉ.
INFÉRIEURE
DEMANDE UNE VITESSE INFÉRIEURE À LA
MOTEUR DE VENTILATEUR
C.I. PRINCIPAL
5 FOIS
SURCHARGE
VITESSE MINIMUM DU COMPRESSEUR
LA TENSION EST EXTRÊMEMENT BASSE.
FUITE DE FLUIDE FRIGORIGÈNE
SURCHAUFFE COMPRESSEUR
AUGM. TEMP.
DÉTECTÉE PAR OH
CIRCUIT OH THEMISTOR
OH THEMISTOR
6 FOIS
THERMISTANCE.
VALEUR ANORMALE
THEMISTOR
THEMISTOR (OUVERT OU
ANORMAL
7 FOIS
COURT-CIRCUIT) DÉTECTÉE.
PAS D'ACCÉLÉRATION SUPÉRIEURE
ÉCHEC
À LA VITESSE MINIMUM POUR LE
D'ACCÉLÉRATION
8 FOIS
COMPRESSEUR.
COMMUNICATION ENTRE UNITÉ
CÂBLE MAL BRANCHÉ.
ERREUR DE
INTÉRIEURE ET UNITÉ
CÂBLE OUVERT.
COMMUNICATION
9 FOIS
EXTÉRIEURE INTERROMPUE
CIRCUIT D'INTERFACE ENTRE
SOURCE
SOURCE D'ALIMENTATION
D'ALIMENTATION
ANORMALE DÉTECTÉE
10 FOIS
ANORMALE
ERREUR DE
RÉGIME VENTILATEUR
BLOCAGE DE
EXTÉRIEUR N'ATTEINT PAS LA
12 FOIS
VENTILATEUR
VALEUR PRÉVUE
EEPROM:
LE MICRO-ORDINATEUR NE PEUT
ERREUR DE
LIRE LES DONNÉES DE LA
LECTURE
13 FOIS
MÉMOIRE MORTE (EEPROM)
EXEMPLE DE
CLIGNOTEMENT (5 FOIS)
COMMUTATEUR DE MAINTENANCE
– 146 –
: CLIGNOTE : ÉTEINT
PAS UN DYSFONCTIONNEMENT
C.I. D'ALIMENTATION
C.I. PRINCIPAL
C.I. PRINCIPAL
COMPRESSEUR
C.I. D'ALIMENTATION
C.I. PRINCIPAL
COMPRESSEUR
C.I. D'ALIMENTATION
C.I. C.I. PRINCIPAL
COMPRESSEUR
C.I. D'ALIMENTATION
COMPRESSEUR
(C.I. PRINCIPAL)
THEMISTOR
BRANCHEMENT DU THEMISTOR DÉFECTUEUX
CIRCUIT THERMISTANCE
FUITE DE FLUIDE FRIGORIGÈNE
COMPRESSEUR
SOURCE D'ALIMENTATION ANORMALE
CÂBLE MAL BRANCHÉ
C.I. D'ALIMENTATION
C.I. PRINCIPAL
MOTEUR DE VENTILATEUR
CIRCUIT MOTEUR VENTILATEUR
C.I. PRINCIPAL
S'ALLUME PENDANT 0,25
SEC À DES INTERVALLES
DE 0,25 SEC.