AEG TH84CB03FB Manuel D'utilisation page 9

Table des Matières
Les langues disponibles

Les langues disponibles

CAUTION!
Connections via contact plugs are
forbidden.
CAUTION!
Do not drill or solder the wire ends. It is
forbidden.
CAUTION!
Do not connect the cable without cable
end sleeve.
N
L1
L2
Two-phase connection: 400 V2N~
5x1,5 mm² or 4x2,5 mm²
N
L1
L2
400V2N~
Green - yellow
Blue and blue
Black
Brown
One-phase connection
1. Remove the cable end sleeve from black
and brown wires.
2. Remove a part of the insulation of the
brown and black cable ends.
3. Connect the ends of black and brown
cables.
4. Apply a new wire end sleeve on the
shared wire's end (special tool required).
220-240 V~
One-phase connection: 220 - 240 V~
5x1,5 mm² or 3x4 mm²
N
L
N
L
Green - yellow
Blue and blue
Black and brown
ENGLISH