Télécharger Imprimer la page

Briggs & Stratton 030372 Manuel De L'opérateur page 18

Les langues disponibles

Les langues disponibles

Service Spark Attester
The engine exhaust muffler has a spark arrester screen.
Inspect and clean the screen every 100 hours of operation or
once eachyear, whichever comes first.
If you use your generator on any forest-covered, brush-
covered, or grass-covered unimproved land, it must have a
spark arrester. The spark arrester must be maintained in
good condition by the owner/operator.
WARNING
e
e
e
Contact with muffler area can result in serious
burns.
_
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
DO NOTtouch hot parts and AVOID hot exhaust gases.
Allow equipment to cool before touching.
Keepat least 5 feet (1.5 m) of clearanceon all sides of
generator including overhead.
Code of Federal Regulation (CFR)Title 36 Parks, Forests, and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDAForest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may havesimilar laws.
1. To remove muffler heat shield (A) from muffler (B),
remove four screws that connect guard to muffler
bracket.
{
Air Cooling System
Over time debris may accumulate in cylinder cooling fins and
cannot be observed without partial engine disassembly. For
this reason, we recommend you have an authorized Briggs &
Stratton service dealer clean the cooling system (D) per
recommended intervals (see Maintenance Schedule in
beginning of Maintenance section). Equally important is to
keep top of engine free from debris. See CleanDebris.
Carburetor Adjustment
The carburetor on this engine is low emission. It is equipped
with a non-adjustable idle mixture valve. Top speed has been
set at the factory. If adjustment is required, see an
authorized Briggs & Stratton service dealer.
CAUTION
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
• DO NOTtamper with governed speed. Generator supplies
correct rated frequency and voltage when running at governed
speed.
• DO NOTmodify generator in any way.
.
3.
Remove four screws that attach spark arrester screen
(c).
Inspect screen and obtain a replacement if torn,
perforated or otherwise damaged. DO NOT use a
defective screen. If screen is not damaged, clean it with
commercial solvent.
4. Reattach screen and muffler guard.
18