Fault Conditions; Data Table - Stiebel Eltron SHP-A 220 Plus Utilisation Et Installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

iNSTAllATiON
Specification
A1
Electronic assembly (control unit)
A2
Electronic assembly (programming unit)
C1
Condenser
E1
Heating element
F1
High limit safety cut-out TSR
F2
Motor overload relay M1
F3
High pressure limiter
F4
Fuse
G1
Impressed current anode
M1
Compressor
M2
Fan
N1
Thermostat TSR

16.3 Fault conditions

WARNING Burns
In the case of a fault, temperatures up to the high limit
safety cut-out limit can occur (see "Specification / Data
table" chapter).

16.4 Data table

Hydraulic data
Nominal capacity
Surface area, indirect coil
Application limits
Max. DHW temperature with heat pump
Max. DHW temperature with emergency/booster heater
Max. permissible DHW temperature inside the cylinder
High limit safety cut-out
Min./max. application limits for heat source
Minimum installation room volume (recirculation air mode, general do-
mestic use)
Maximum permissible operating pressure, cold water/DHW
Min./max. conductivity, drinking water
Output data to EN 16147
Nominal DHW temperature (EN 16147)
Nominal load profile (EN 16147)
Reference DHW temperature (EN 16147 / A20)
Reference DHW temperature (EN 16147 / A15)
Reference DHW temperature (EN 16147 / A7)
Maximum available nominal amount of DHW at 40 °C (EN 16147 / A20)
Maximum available nominal amount of DHW at 40 °C (EN 16147 / A15)
Maximum available nominal amount of DHW at 40 °C (EN 16147 / A7)
Rated heating output Prated (EN 16147/A20)
Rated heating output Prated (EN 16147 / A15)
Rated heating output Prated (EN 16147 / A7)
Heat-up time (EN 16147 / A20)
Heat-up time (EN 16147 / A15)
Heat-up time (EN 16147 / A7)
Power consumption, standby period (EN 16147 / A20)
Power consumption, standby period (EN 16147 / A15)
Power consumption, standby period (EN 16147 / A7)
COP (EN 16147 / A20)
COP (EN 16147 / A15)
COP (EN 16147 / A7)
Heating output
Average heating output (A20 / W10-55)
Average heating output (A15 / W10-55)
Average heating output (A7 / W10-55)
www.stiebel-eltron.com
R1
Resistance
S1
DIP switch
S2
DIP switch
T1
Temperature sensor (cylinder top/integral)
T4
Temperature sensor, evaporator
X0
Mains terminal
X1
Terminals
X3
Terminals
Behälter Cylinder
Deckel
Cover
Mantel
Jacket
SHP-A 220 Plus
238633
l
220
°C
65
°C
65
°C
°C
92
°C
+6/+42
23
MPa
0.8
μS/cm
100-1500
°C
55
L
°C
52.6
°C
52.7
°C
54.0
l
278
l
277
l
254
kW
1.6
kW
1.45
kW
1.01
h
6.06
h
6.65
h
8.78
kW
0.022
kW
0.027
kW
0.035
3.55
3.20
2.68
kW
1.9
kW
1.6
kW
1.3
SHP-A 300 Plus
SHP-A 300 X
238634
302
65
65
92
+6/+42
23
0.8
100-1500
55
XL
54.4
54.1
54.2
395
412
410
1.52
1.63
1.14
9.05
8.83
12.52
0.024
0.028
0.040
3.51
3.26
2.79
1.9
1.6
1.3
SHP-A 220-300 Plus |
Plus
238635
291
1.3
65
65
70
92
+6/+42
23
0.8
100-1500
55
XL
54.4
52.5
52.6
371
387
381
1.43
1.41
1.07
9.05
9.60
12.43
0.028
0.032
0.044
3.51
3.30
2.75
1.9
1.6
1.3
31

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Shp-a 300 plusShp-a 300 x plus

Table des Matières