CLEANING THE CATALYTIC CONVERTER

To be carried out if you suspect poor incineration or a cycle of 30 days' use has been completed.
1. Wait for the toilet to cool down and the fan to stop.
2. Pull the toilet shell out from the rear wall. The shell will automatically move out and up with the
help of a inside lifting mechanism and remain in the service position.
3. Lift the shell completely off the lifting mechanism (Illustration 9).
4. Loosen the screw on the fan cover (Illustration 10).
5. Remove the fan cover. Loosen it from the retaining screw by turning it slightly backwards.
Then lift it out (Illustration 11).
6. Remove the catalyst pipe with the catalytic converter (Illustration 12).
7. Rinse the catalytic converter in warm water (Illustration 13).
8. Reassemble the parts in reverse order. Make sure that the catalyst pipe is put in the same position
as it was before disassembly.
9. Place the toilet chamber back onto the lifting mechanism.
10. Run a dry incineration cycle (by pressing the start button) to dry out the catalytic converter.
Illustration 9
Illustration 10
Illustration 12
Illustration 13
10
Illustration 11

TROUBLESHOOTING

Yellow
Error
Red light
Green light
light
Problem with
Flashing
Flashing
exhaust fan.
Problem with
Flashing
Flashing
Flashing
gas fan.
Problem with gas
burner after 3
Flashing
attempts to ignite it.
Hatch is jammed.
Flashing
Ash container
is not in correct
Flashing
Flashing
position.
Error in the
temperature
Flashing
Flashing
sensor
Thermal switch
Illuminated
released.
The ash container
is full. The toilet is
Illuminated
Illuminated
disabled for use.
No lights, no
sound.
Burnt smell
outside caravan/
motor home.
Low voltage
Flashing
< 11.0 V.
Minimum allowed
voltage < 10.5 V.
Flashing
The gas supply is
(after 1.5 min)
shut off.
Critically low
voltage. Immediate
shut-down.
NOTE!
Reset the toilet by holding the start button down for 8 seconds.
You can release the button when you hear a long beep.
Sound signal
Remedy
1.
Reset the toilet.
2.
Open and close the toilet lid.
10 beeps
3.
Start incineration.
4.
If error recurs, contact dealer/
service.
1.
Reset the toilet.
2.
Open and close the toilet lid.
10 beeps
3.
Start incineration.
4.
If error recurs, contact dealer/
service.
1.
Check that the gas is connected.
2.
Connect it if necessary and reset the
toilet.
Continuous
3.
Reset the thermal switch if needed.
beeps
4.
Open and close the toilet lid.
5.
Start incineration.
6.
If error recurs, contact dealer/
service.
When toilet is warm:
1.
Press the start button multiple times
without inserting a new bowl liner.
2.
Open the lid after each attempt. If
this does not work, wait for the toilet
10 beeps
to cool down (fan has stopped).
When toilet is cold:
1.
Open the toilet lid and press start.
The lid opens.
2.
Remove the cause of the blockage.
3 beeps
Place ash container into correct position.
Try to reset the toilet. If this does not
Continuous
work, contact workshop or dealer.
Reset thermal switch (see separate
Continuous
section).
Continuous
Empty and clean ash container.
Check that the caravan's/motor home's
main switch is on. Check that 12 V voltage
is connected.
Clean catalytic converter. Ensure that the
exhaust pipe is open.
Resolve the error on the 12 V supply from
the car/caravan.
10 beeps,
Resolve the error on the 12 V supply from
recurrent
the motor home/caravan.
Resolve the error on the 12 V supply from
10 beeps
the motor home/caravan.
11