7. ERROR CODES

The following table summarize the errors codes the display shows to the operator and
the related description.
Type
Description
E01
Safety level of balance tank
not reached.
Autoresettable.
E02
Water flow or temperature
failure.
Automatically self-operational
alarmAutoresettable.
E04
Water temperature is too high.
Automatically self-operational
alarm Autoresettable.
E05
Water temperature sensor.
Autoresettable.
E07
Heater contactors.
E08
Not Autoresettable.
E09
Max. time of the balance tank
water filling exceeded.Not
Autoresettable.
E10
Balance Tank Water levels
signals are incompatibles.
Autoresettable.
E11
Water level in the balance tank
is below safety sensor.
Autoresettable.
E0
Communication between
Panel Control Board and local
Cn
keypad.
44
Cause
The Safety level sensor of the
balance tank doesn't detect
water.
No function can be activated.
Flow sensor doesn't
detect water flow or
temperaturesensor doesn't
send any signal.
No function can be activated.
The water temperature inside
the Spa is over 42°C.
No function can be activated.
The temperature sensor is
malfunctioning.
No function can be activated.
The heater contactors are
malfunctioning; you cannot
activate the electrical heater.
The max opening time (30') of
the loading electrovalve of the
balance tank has been reached
Water level sensors are sending
incompatible signals.
Some function is trying to be
activated before the minimum
level inside the balance tank
has been reached (or when
working, the level is below the
safety sensor).
Communication between Panel
Control Board and local keypad
is lost.
Solution
Fill the balance tank until minimum sensor
level.
Check possible obstructions in the filtering
circuit, pumps, or filter.
Check possible sensor malfunction.
Let the water cool or add cool water.
When the temperature will be below 42°C
your SPA will start up automatically; if not
unplug the power supply and contact your
dealer.
Check the water temperature and
temperature sensor and replace it if needed.
For safety reasons, the electric heater is
powered by two contactors, which are
serially connected; if one of these two
contactors is stuck, an error message will
appear.
Replace corresponding contactors and plug
the elements again.
Make sure that the sensors of water level
of the balance tank work properlyMake
sure that the discharge hole has been left
open.Check a possible water leakage in the
hydraulic circuit.
Check position of the level sensors or replace
them if they are malfunctioning.
Make sure that the loading electrovalve
is open and works properly. Make sure
there's no obstruction in the water charging
circuit. Verify there's no water leakage in the
hydraulic circuit.
Make sure that the cable between the
local keypad and the Panel Control Board
is connected properly. If it is, unplug the
system from the mains and get in touch with
your dealer.