Iberspa Oasis 40 Manuel D'utilisation Et D'installation page 33

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 88
S0
Safety probe
SMIN
Mínimum level probe
SMAX Maximum level probe
EL
Electric control box
EV
Electric valve (not included)
S0 sensor has to be placed above the bottom outlet pipe.
Smin sensor has to be placed above S0 sensor.
There must be more water than the volume displaced by all bathers between Smin
and Smax. Smax has to be placed below the top drain..
The level sensors have to be attached to outer side of the balance tank.
The system will be automatically blocked when water level is below so sensor.
The electric valve (EV) will be activated (the tank will start filling) when the level drops
to below SMIN and will be deactivated when it exceeds SMAX.
If you do not install level sensors, follow the next diagram.
M6
K1
E5
F3
SAT
J4
L3
N3
K3
K2
N2
L2
J5
F2
K4
K7
K6
K14
K3
LINE
A
B
C
D
Ht
V1
M5
C2
M9
V1
F6
2SAT
C3
J6
M7
J7
M8
F4
SAT
IC2
L4
N4
N5
L5
N6 L6
J2
V1
M1
Network water inlet
Deposit overflow
Spa overflow water inlet
Water outlet towards filtration
Total height
M9 compensation vat
(capacitive Level switch)
1= N.U.
2= Safety level (YELLOW)
3= Min level (YELLOW)
4= Max level (YELLOW)
5= GND (GREEN 3 wires)
6= +5Vdc (BROWN 3 wires)
M4
K10
M3
V2
J3
L7
N0
N7
M2
ENG
124
33

Publicité

Table des Matières