to below 6° C, the device will switch on au-
tomatically. This is to prevent the heating
agent inside the radiator from freezing. The
activation of Anti-freeze mode is indicated
by the blinking of the middle diode.
Dryer function
The Dryer turns the device on for 2 hours,
e.g. in order to dry a towel. After this peri-
od of time the device automatically switch-
es to the mode to which it was set before
the dryer mode.
Dryer function can be activated during heat-
er operation by pressing button. You can
now freely adjust desired temperature lev-
el (buttons and ). After 2 hrs heater will
revert to the previous setting (before dryer
function activation). To use 2 hrs timer heat-
ing element must be switched off. Switch it
on by pressing button. After 2 hrs heater
will switch off automatically.
Press button at any time to interrupt the
dryer mode.
Calibrating the temperature span
The standard temperature span of the heat-
ing element is 30-60° C. It is possible to in-
crease or decrease that span by setting
a maximum temperature of between 45° C
and 65° C, (minimum temperature of 30° C
EN
stays unchanged). This allows the user to
achieve a maximum temperature which is
higher than the standard or to effectively
heat a space with the device during lower
surrounding temperatures.
Example: for the temperature regulation
span of up to 45° C (30-45° C) modification
by one step (one diode), means increase/
decrease of temperature by 3.75° C, while
for the temperature regulation span of up
to 65° C (30-65° C) modification by one step
means increase/decrease by 8.75° C.
In order to modify the temperature span,
unplug the device and plug it back in, while
pressing
button. A single diode will start
blinking on the display panel. Use
buttons to set one of the 5 possible maxi-
mum temperatures. The first diode stands
for 45° C. The following diodes refer to the
following maximum temperatures: 50° C,
55° C, 60° C and 65° C.
After selecting the new temperature span
press on/off button to store the new settings.