Fault
Thetemperature in the
freezer compartment is too
warm.
Freezercompartment door
was open for a long time;
temperature is no longer
reached.
Customer
service
Your
local customer
service
in the telephone directory or in the
customer service index. Please provide
customer service with the appliance
product number (E Nr.) and production
number (FD).
16
Possible
cause
• Freezercompartmentdoor is
open.
• The ventilationopeningsare
blocked.
• Too muchfood was placedin
the freezercompartmentat
once.
The evaporator(refrigeration
generator) in the Nofrost system
is covered in thick ice and can
no longerbe defrostedfully
automatically.
This information
product label. Fig.
To prevent unnecessary call-outs, please
can be found
assist customer service by quoting the
product and production numbers. This
will save you additional costs.
Remedial
action
Close the door.
Ensurethat there is adequate
ventilation.
Donot exceedmax.freezing
capacity.
To defrostthe evaporator, r emove
the frozen food with the
compartments,insulatewell and
store in a cool location.
Switch off the appliance and move
it awayfrom the wall. Leavethe
appliancedooropen
After approx.20 min.the
condensation beginsto run intothe
evaporationpan, Fig.@ at the rear
of the appliance.To preventthe
evaporationpan from overflowingin
this case,mop up the condensation
with a sponge.
The evaporator is defrosted when
the water stopsrunninginto the
evaporationpan. Cleanthe interior.
Switchthe applianceback on again.