CAUTION:
• Do not exceed the current limit specified for any one receptacle.
• Do not modify or use the generator for other purposes than it is intended
for. Also observe the following when using the generator.
• Do not connect an extension to the exhaust pipe.
• When an extension cable is required, be sure to use a tough rubber
sheathed flexible cable (IEC 245 or equivalent).
When using an extension cable the resistance value shall not exceed
1.5 Ω.
• Limit length of extension cables; 60 m (200 feet) for cables of 1.5 mm
2
(0.0023 in
) and 100 m (330 feet) for cables of 2.5 mm
extension cables will lower usable power due to resistance in the
extension cable.
• Keep the generator away from other electric cables or wires such as
commercial power supply lines.
GW1 Type
When connecting an angled plug, be sure to use only a IPx4 plug.
NOTE:
• Most appliance motors require more than their rated wattage for startup.
Make sure the electrical rating of the tool or appliance does not exceed the
maximum power rating of the generator.
Maximum power is: 1.0 kVA
• For continuous operation, do not exceed the rated power.
Rated power is: 0.9 kVA
• In either case, the total power requirements (VA) of all appliances connected
must be considered.
• The DC receptacle can be used while the AC power is in use.
If you use both at the same time, do not exceed the maximum AC power.
Maximum AC power: 0.8 kVA