3 Installation
Fig. 2: Mounting of stainless steel column
For mounting, MENNEKES recommends threaded bolts and nuts both made of stainless steel with a strength class of at
least 8.8. Use only threaded bolts and nuts made of stainless steel to prevent corrosion.
A separate supply line should be provided for each AMTRON® charging station.
Create bedplate using six threaded bolts M10
A
the prefabricated bedplate" on page 6. Cable length from top edge of bedplate approx. 2.5 m!
Alternatively, a prefabricated bedplate can be purchased directly. Please refer to Page <dg_ref_source_iline>Bestellinfos
Fundament</dg_ref_source_inline>.
Remove bolts
on the base plate; use the supplied bit insert for this purpose. Slide cover
B
2
Set the stainless steel column on the bedplate. Feed connection cable
C
uppermost cable outlet of the stainless steel column.
Bolt stainless steel column down using six VA nuts M10 and tighten using a torque wrench (tightening torque depends
D
on selected threaded bolt size).
If necessary, integrate the stainless steel column into the equipotential bonding / earthing system. A connection point is
provided on the stainless steel column's base plate for this purpose.