INSTALLATION INSTRUCTIONS
INSTALLER MENU (cont)
Installer's
Description
Menu #
(Hold Menu
3 Seconds)
20
Algorithm – AC or HP (If HP
is selected, item #32 will be
displayed)
CR
Heat Cycle Rate (how often the
30
heat will turn on)
Aux Cycle Rate (how often the
CR
32
auxiliary heat will turn on) NOTE:
Available if HP is selected on
item #20
Cool Cycle Rate (how often the
CR
35
cooling will turn on)
CL
Compressor Lockout (protects the
50
compressor from short cycling)
65
Maximum Heat Limit (maximum
set point for heat mode)
66
Minimum Cool Limit (minimum set
point for cool mode)
74
Schedule Type (set as either
7-Day, 5-1-1 Day or Non-
Programmable)
E
Early Start (starts heating or
76
cooling early so your programmed
temperature is reached by the
programmed time)
79
Fahrenheit or Celsius
81
Temperature Display Adjustment
(adjust the displayed "Room
Temperature")
dL
Continuous Display Light (keep
83
the backlight always on – "C" wire
required)
86
Change Air Filter (set up a
monthly reminder)
49-5000770 Rev. 1
Default Setting
Settings
(flashing
icons)
HP
HP – Heat Pump or
AC – Air Cond.
SLO
SLO – slow
MEd – medium
FAS – fast
SLO
SLO – slow
MEd – medium
FAS – fast
SLO
SLO – slow
MEd – medium
FAS – fast
OFF
On – 5 minute delay
OFF – no delay
85°F
45°F to 99°F
60°F
45°F to 99°F
7
7 – 7 Day
5 – 5-1-1 Day
0 – Non Programmable
OFF
On – start early
OFF – start at program
period time
ºF
°F – Fahrenheit
°C – Celsius
0
-5 to +5
OFF
On – always on
OFF – momentarily on
for 8 seconds
OFF
1 to 12 – reminder time
(months)
OFF – no filter reminder
5