4
▼
5
SET
code SET UP THE PROJECT
F0
Set the temperature
F1
Temperature difference value
F2
Refrigeration regression
F3
Control mode
Water temperature super high
F4
alarm
F5
Water temperature ultra-low alarm
F6
Temperature super high alarm
F7
password
F8
Maximum set water temperature
F9
Minimum set water temperature
In the non-set state, press the ▽ key to display the
Check room
detection value of the room temperature sensor, and
temperature
resume the display of water temperature after 6 seconds
(at this time, the room temp light is on, indicating that the
upper window is displayed as room temperature)
Press the SET button when the thermostat is working
normally, if the thermostat is working in constant
temperature mode, the panel will display the parameter
value of F0 (set temperature), and the parameter value
Quick
of
adjustments
displayed in the smart mode (at this time, the panel
PARAM set light will be on, indicating that the
controller is now setting the parameter state). At this
time, press the ▲▼ key to modify the setting value, and
then press the SET key to exit or exit without pressing the
button within 20 seconds. If you press the enter key to
save the disk and exit, the new parameters will take effect.
MENU DESCRIPTION
RANGE
F9~
F8/-20~40
– 15~5
0.1~9.0
0~1
1~80
1~40
40~50
00~99
(F9+1)~
50
-30~(F8
-1)
F1 (temperature difference value) will be
DEFAUL
T VALUE
25.0
-2
0.8
1
10
15
45
06
30
20
- 9 -
REMARK
Smart temperature control mode
constant temperature mode
1 Smart, 0 Constant
Temperature