DIGIT KEYSTROKE FUNCTION DESCRIPTION OF THE OPERATION
1
SET+Enter
2
▲+SET
3
▲+▼
Press and hold the Enter key and the SET key,
"99" will be displayed after three seconds, press the
▲▼ key to modify the password "XX" of the factory
settings, press the SET key to enter the menu settings,
Manufacturer
you can modify the factory settings, and you can change
parameter
the (F0-A11) parameters. Press the Enter key any time to
adjustment
save the modified parameters, exit the parameter setting
state, return to the temperature display, and run according
to the new parameters. If no button is pressed within 20
seconds, the controller will automatically exit the
parameter setting state and will not save the modified
parameters. If the password is incorrect, press SET to
return to the temperature display
1.▲▽ Key change parameter value, key change
parameter item, ◀ ▶ enter key save exit.
2. Press and hold the ▲ key first, and then press the SET
button at the same time for five seconds The upper limit
window displays "00", and the lower display window
displays "PAS", at this time, press the ▲▼ key to select
the password that has been set, and then press the
SET key, if the password is correct, the lower
display window displays the parameter item F0, and the
User
upper display window displays the parameter value of F0,
parameter
and enters the setting state, indicating that the controller is
adjustments
now in the parameter setting state. If the password is
incorrect, the temperature display will be returned. After
entering the setting state, press the left and right keys to
change the parameter item in turn, and press the key ▲▼
to change the parameter value of the parameter item.
Press the enter key at any time, save the modified
parameters, exit the parameter setting state, return to the
temperature display, and run according to the new
parameters. If no button is pressed within 20 seconds,the
controller will automatically exit the parameter setting state
and will not save the modified parameters. In the state of
parameter setting, pressing SET does not respond
When the power is on and the normal display, when the
Quickly
tempera- ture is not set, press and hold the ▲▼ button at
restore factory
the same time, the thermostat will be powered on, and
settings
"rE" will be displayed after three seconds, and all the set
values will be restored to the factory value, and then return
to normal working state after 3 seconds.