6. Commissioning, operation
Fitting the DIN 175301-803 angular connector
1. Loosen the screw .
2. Loosen the cable gland .
3. Pull the angled socket  +  from the instrument.
4. Via the mounting hole , lever the terminal block 
out of the case .
5. Pass the cable with the appropriate cable outer
diameter through the cable gland , ring ,
sealing  and the case .
6. Connect the cable ends to the connection termi-
nals on the terminal block  in accordance with the
pin assignment (see "Connection diagrams" for the
pin assignment).
7. Press the terminal block  into the case .
8. Tighten the cable gland  around the cable.
Make sure that the cable gland and seal are not
damaged and that they are assembled correctly in
order to ensure ingress protection.
9. Place the flat, square gasket  over the pressure
sensor's connection pins.
10. Slide the assembled angled socket  +  onto
the pressure sensor's connection pins.
11. Using the screw , screw the angled socket to the
pressure sensor, hand-tight.
6.3 Commissioning of USB instruments
For installing the driver, administrator rights are required.
Connect the USB connector to a USB 2.0 port at your computer.
Install the driver via the InstallWizard of the product software.
For further operation the P-3x data logger software is available (for details see
instruction manual P-3x data logger).
Details on the interface protocol or the DLL (Dynamic Link Library) are available on
the software CD and in the download section at www.wika.com.
For the model HP-2, model P-30 software must be used. All files and
documents are available for download at www.wika.com.
WIKA operating instructions pressure sensor, model HP-2
 Mounting hole
EN
13