PRO-POINT 8475006 Manuel D'utilisation page 12

Table des Matières
Les langues disponibles

Les langues disponibles

V 1.6
DISPOSAL
Recycle a device damaged beyond repair at the appropriate facility.
Contact your local municipality for a list of disposal facilities or by-laws for electronic devices,
batteries, oil or other toxic liquids.
IMPORTANT! DO NOT pollute the environment by allowing uncontrolled discharge of waste oil.
TROUBLESHOOTING
Contact Princess Auto Ltd. for a solution if the device does not function properly or parts are
missing. If unable to do so, have a qualified technician service the device.
Problem(s)
Pump is slow to
build
tank pressure.
Excessive oil
consumption.
Low discharge
pressure.
OR
Compressor does
not stop.
Air leaks
from regulator.
Or
Regulator does
not
regulate pressure.
12
60 Gallon Single Stage Stationary Air Compressor
Possible Cause(s)
1. Loose/slipping belt.
2. Leaks in system.
3. Blown gasket.
4. Broken reed valve.
5. Obstructed intake filter.
6. Leaking regulator.
7. Defective pressure
relief valve.
1. Too much oil in crankcase.
2. Improper weight of oil.
3. Obstructed
crankcase vent.
4. Dirty/plugged intake filter.
5. Worn piston rings.
6. Scored cylinder.
1. Tank drain valve is open.
2. Air leaks.
3. Restricted air intake.
4. Prolonged excessive use
of air.
5. Compressor not
large enough.
6. Tank leaks.
7. Blown seals or gaskets.
8. Leaking/worn piston rings
or cylinder.
Dirty or damaged regulator
internal parts.
Suggested Solution(s)
1. Adjust belt tension.
2. Correct air leaks.
3. Replace head gaskets.
4. Replace reed valves.
5. Clean or replace intake element.
6. Replace regulator.
7. Replace pressure relief valve.
1. Drain to proper level.
2. Replace with proper oil.
3. Replace dipstick or oil fill plug/
crankcase vent.
4. Clean/replace intake filter.
5. Contact Princess Auto Ltd.
for solution.
6. Contact Princess Auto Ltd.
for solution.
1. Close drain valve.
2. Tighten or replace leaking fittings or
connections (do not overtighten).
Check air hose. Replace parts
if necessary.
3. Clean or replace air filter element(s).
4. Decrease amount of air used.
5. Check air requirement of accessory.
If it is higher than CFM and pressure
supplied by compressor, you need a
larger compressor. Most accessories
are rated at 25% of actual CFM while
running continuously.
6. Immediately replace tank. DO NOT
attempt to repair.
7. Replace seals or gasket.
8. Replace piston ring or cylinder.
Replace regulator or internal parts.
For technical questions call 1-800-665-8685
8475006
Table des Matières
loading

Table des Matières