Télécharger Imprimer la page

GE GeoSpring GEH50DEEDSRA Manuel D'utilisation Et D'installation page 21

Publicité

Les langues disponibles

Les langues disponibles

Fault codes.
GEApp,i°nces.com
Fault Code
Displayed
Condition
Action
F-A
T4 Not Rising
Call service
F-B
Discharge Ternp Not Stable
Call service
F-C
Evaporator Not Frost Free
Call service
F-D
Superheat Too Low
Call service
F-E
Discharge Temperature Above Limit
Call service
F-F
Electronic Expansion Valve Out of Range
Call service
F2
T2 Tank Temperature Sensor Failure
Call service
F-3
Compressor Failure
Call service
F-4
Fan Failure
Call service
F-5
T3a Sensor (Evap inlet temperature) Failure
Call service
F-6
T3b Sensor (Evap outlet temperature) Failure
Call service
F-7
T4 Sensor (Compressor outlet) Failure
Call service
F-8
T5 Sensor (ambient temperature) Failure
Call service
F-9
Lower Heating Element Failure
Call service
F-IO
Upper Heating Element Failure
Call service
F-II
Dry Tank Fault
See page 16
F13
Stuck Key Fault
Call service
F15
DataFlash Fault
Call service
bAd linE
The voltage is too low at power-up
See page 16
Note: If your unit shows "PS" on the display when trying to adjust the temperature, this is not a
fault code. "PS"indicates that the unit is operating with the ACM module and is in Power Saver
mode. See page 10 for details.
21

Publicité

loading

Ce manuel est également adapté pour:

Geospring geh50deed serieGeospring geh50deedsca