Connecting the Components

Use the following procedure as a guideline for making the
connections between the components of the remote frost top
drop-in shelf system. These connections must be made by
trained and qualified installers and must comply with all local
plumbing and electrical codes. Refer to the SPECIFICATIONS
section and the wiring diagram included with the unit for details
regarding the plumbing and electrical connections.
1. Connect the liquid and suction refrigerant lines between
the condensing unit, the TXV valve, and the frost top
enclosure evaporator coil. Refer to the appropriate
illustration below and the SPECIFICATIONS section for
connection details.
NOTE: The maximum refrigerant line length between the
condensing unit and the evaporator coil is 50 feet (15 m).
NOTE: For refrigerant line connections, use a self-fluxing
brazing compound (example = Sil-Fos 5
temperature range of 1300–1500°F (704–816°C).
Frost Top Enclosure
Liquid Connection
(3/8" O.D. tube)
Liquid Connection
(1/4" O.D. tube)
FTBR Model Refrigerant Connections
Form No. FTBRM-0717
) at a brazing
®
Suction Connection
(3/8" O.D. tube)
Fasten TXV bulb to
the suction side of
evaporator coil here.
TXV Bulb
TXV Valve
Condensing
Unit
Suction Connection
(3/8" O.D. tube)
Liquid Connection
(3/8" O.D. tube)
F r o m
C o n d
e n s i n
g
U n i t
Solenoid Valve
FTBX Model Refrigerant Connections
2. Have a qualified electrician make the appropriate electrical
connections to the control panel. Refer to the wiring
diagram for details.
For FTBR Models:
a. Connect the on-site power
supply through the power
input
knockout
POWER IN terminal block.
b. Connect power from the
POWER OUT terminal block,
through the power output
knockout, to the power input
on the condensing unit.
c. Connect the temperature
probe wire from the frost top,
through the probe wire inlet,
to the digital temperature
controller.
Temperature Probe
Wire Inlet
Power Output
(to condensing unit on
FTBR Models or solenoid
valve on FTBX Models)
Power Input
Control Panel Connections
9
INSTALLATION
Frost Top
Enclosure
Suction Connection
(3/8" O.D. tube)
T o C
o n d e
U n i t
TXV Valve
to
the
Condensing Unit
Power Input
Digital Temperature
Controller
Terminal Blocks
Access Cover
continued...