Atlantic F18 Notice D'utilisation Et D'installation page 8

Convecteur électrique programmable
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Plinth bottom version
2-2 ) Connect the panel heater
- The panel heater must be powered with 220-240V 50Hz
- The panel heater must be connected to the mains by a 3-
wire cable ( Brown= Phase, Blue=Neutral, Black=Pilot wire
) by means of a connection box. In humid areas such as
bathrooms and kitchens the connection box must be
installed at least 25 cm above the floor.
- Earthing is prohibited.
Do not connect the pilot wire ( black ) to earth.
- The heater must be installed by a qualified electrician in
accordance with the local regulations. The heater and the
pilot (black) wire must NOT be connected to earth. If the
heater wire is damaged, he should be replaced by the
manufacturer, his service after sale or a person of similar
qualification to avoid a danger.
If a pilot or piloted panel heater is protected by a 30mA
differential (e.g. bathroom) the pilot wire's power supply.
Absence de
Ordres reçus
courant
Oscilloscope
Réf/Neutre
Mode obtenu
CONFORT
1) Description of the control unit :
Mode cursor.
Comfort temperature set value adjustment knob.
Eco temperature set value adjustment knob.
V1
Heating light.
V2
Eco mode light.
V3
Comfort mode light
2) Fixing the comfort temperature :
The comfort temperature is the temperature that you would like while the room is occupied.
a) Set the cursor
to
, the light V3 comes on.
b) Adjust knob
to 5, the heating light V1 comes on if the ambient temperature is below the required temperature.
c) Wait for a few hours until the temperature stabilizes.
d) If you are happy with the setting (use a thermometer to check if you wish) mark the position once and for all.
Otherwise, modify the setting and return to item c).
Alternance
Alternance
absence de
absence de
courant (4'57'')
courant (4'53'')
phase
phase
230V(3'')
230V(7'')
CONFORT
CONFORT
-1°C
-2°C
II - U
SING THE PANEL HEATER
Phase = brown
Neutre = blue
Pilote wire = black
3 possibles cases
1
case : only one heater
st
2
nd
cas : multiple heaters
3
rd
cas : master device
Demi-alternance
Alternance
négative
complète 230V
-115V
ECO
HORS GEL
1
V1
V1
V2
V2
PHASE
Electricity grid
NEUTRAL
The pilote wire free end is
insulated and not further connected
The pilot wire of all heaters in a control
group, up to a maximum of 20 units with any
one the used as the master are connected by
a 1.0mm* 220/240 V insulated cable
To pilot wire of an electronic
regulated device
Demi-alternance
positive +115V
ARRET
DELESTAGE
V3
V3
GB

Publicité

Table des Matières
loading

Table des Matières