Installation Instructions
Owner's Manual for Auto Generator Start functionality.
OPTIONAL: All controls are equipped with furnace
operation functionality. To use this feature, connect your
RV's furnace to the terminals labeled "FUR" on the 4-pin
connector.
10. Rotate lower section of control box upwards making
sure not to crush any wires. Drive three screws,
securing he control box closed. The main control
install is now complete.
11. Remove the Wall Thermostat cover from the base
by releasing the plastic snap at the bottom of the
assembly. This can be done by inserting a flathead
screwdriver into the rectangular notch at the bottom
of the wall thermostat assembly, and then rotating the
screwdriver 90° as shown in the figure on page 5.
12. Put thermostat base against the wall where you
plan to mount it. Make sure wires will feed through
the wire opening in the base of the thermostat.
13. With the base level, mark the placement of
themounting holes.
14. Ensure no other wires are affected by the drilling of
1/8" holes.
15. Using a 1/8" drill bit, drill pilot holes in the locations
you have marked for the wood screws.
16. Align thermostat base with mounting holes and
feed the control wires through the wire opening.
17. Use supplied screws to mount thermostat base
to wall.
18. Insert stripped, labeled wires in matching wire
terminals and tighten terminal screws once properly
aligned. See the "Wiring Diagrams" section of this
manual.