8. Mate the thermistors to the corresponding
interconnects on the main board. These will be
bundled with the 3 & 4-pin connector in the rooftop
unit. For ARC models, one connection will need to
be made (indoor coil and indoor air outlet sensor).
For ARH models, an additional connection will need
to be made (ambient/outdoor coil sensors).
9. If you are using an RGREC3A or RGREC2A
control, with an RGRWT wall thermostat, connect
12VDC and 0VDC supply from your RV to the 2-pin
connector with terminals labeled 12V and GND
respectively. Then, connect 3 wires to the 3-pin
connector with terminal labels A, B, & C, taking
note of which color wire was connected to which
terminal—we will connect the other ends to our
thermostat later. If you are using an RGREC1A
control, connect the 4-pin RV-C connector coming
from your all-in-one control to the "RVC-1" or
"RVC-2" connector on the board. If you are only
using 1 RV AC in your RV, or this is the last RV AC
in your setup, connect a 4-pin RV-C connector with
a terminating resistor to the RV-C terminal that has
not been used.
OPTIONAL: If you are using an RGREC1A or
RGREC2A control, you have the option to connect your
control to your RV's load shed system via the 2-pin
connector terminal labeled LS or the 8-pin connector
terminal labeled LS. See your RV Owner's Manual for
load shed management.
OPTIONAL: If you are using an RGREC1A or
RGREC2A control, you have the option to connect to an
"Auto Generator Start" feature. To do so, connect via the
4-pin connector terminals labeled "GEN". See your RV
6