Information Screens - Cembre B1350-UC Notice D'utilisation Et Entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7. DISPLAY
The OLED display switches on automatically when the operating or pressure release buttons are
pressed, and off after 60 seconds of non-operation.
The display shows:
The main operational parameters of the tool processed by the circuit board, such as peak pres-
sure or force reached.
Information on the condition of the tool, such as the charge level, the battery temperature and
maintenance requirements.
Any operational or procedural ERRORS.
Use the touch button (8) to navigate through the menu screens to manage INFORMATION AND
SELECTION:

7.1) INFORMATION SCREENS:

time the tool is started and during the entire work cycle.
Fm: Minimum set force, expressed in kN.
F
= 125.2 kN
m
Fp: Peak force reached, expressed in kN,
Fp = 94.5 kN
(screen as factory setting).
Fm: Minimum set force, expressed in USA sh. tons.
F
= 14.07 ton
m
Fp: Peak force reached, expressed in USA sh. tons.
Fp = 10.61 ton
P
= 692 bar
Pm: Minimum set pressure, expressed in bar.
m
Pp: Peak pressure reached, expressed in bar.
Pp = 522.3 bar
P
= 10037 psi
Pm: Minimum set pressure, expressed in psi.
m
Pp: Peak pressure reached, expressed in in psi.
Pp = 7575 psi
Battery charge level.
BATTERY
1000
No. of cycles performed.
No. of cycles before scheduled recommended maintenance.
-12000
Cembre logo, tool model.
B1350
Tool serial no.
NR 13AB485
display a pre determined parameter which will then appear each
14

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

B1350-ucaB1350-uceB1350-uct

Table des Matières