7. DISPLAY
The OLED display (8) switches on automatically when the operating or pressure release buttons are
pressed, and off after 60 seconds of non-operation.
The display shows:
- The main operational parameters of the tool processed by the circuit board, such as peak pres
sure or force reached.
- Information on the condition of the tool, such as the charge level, the battery temperature and
maintenance requirements.
- Any operational or procedural ERRORS.
Use the touch button (7) to navigate through the menu screens to
manage INFORMATION AND SELECTION:

7.1) INFORMATION SCREENS:

appear each time the tool is started and during the entire work cycle.
Fm: Minimum set force, expressed in kN.
F
= 125.2 kN
m
Fp: Peak force reached, expressed in kN,
Fp = 94.5 kN
(screen as factory setting)
F
= 14.07 ton
Fm: Minimum set force, expressed in USA sh. tons.
m
Fp: Peak force reached, expressed in USA sh. tons.
Fp = 10.61 ton
P
= 692 bar
m
Pm: Minimum set pressure, expressed in bar.
Pp = 522.3 bar
Pp: Peak pressure reached, expressed in bar.
P
= 10037 psi
m
Pm: Minimum set pressure, expressed in psi.
Pp = 7575 psi
Pp: Peak pressure reached, expressed in in psi.
Battery charge level.
BATTERY
1000
No. of cycles performed.
-12000
No. of cycles before scheduled recommended maintenance.
Cembre logo, tool model.
B1300
Tool serial no
NR 15AA190