4. TROUBLESHOOTING

PROBLEMS
FILTERING
Insufficient flow of filtered water.
MASSAGE
The massage pump does not
activate.
Low air flow in the jets.
Water leaks out through the
Venturi.
It does not work.
AIR HYDRO MASSAGE
Limited air flow.
Air pump does not activate.
It does not work.

HEAT EXCHANGER

Thermostat does not properly
indicate the temperature.
Water does not reach the
required temperature.
It does not work
REASONS
Filter blocked by dirt.
The cable of the digital control panel is
disconnected.
Key air bulb disconnected.
Venturis are closed or blocked.
Outer trim of the jet is not properly
installed.
Fuse is blown.
Starter brushes of the motor are worn.
The cable of the digital control panel is
disconnected from the board.
Key air bulb deteriorated.
Fuse is blown.
Temperature probe out of place.
Probe is damaged.
The heat exchanger does not work.
Fuse is blown.
13
English
SOLUTIONS
Wash the filter.
Connect the cable.
Replace bulb.
Open the Venturis.
Clean obstacles
Check jets.
Start up the pump again.
Change starter brushes.
Connect the cable.
Replace bulb.
Start up the pump again.
Place the probe properly.
Replace probe.
Heat exchanger switch in
position OFF.
Start up the safety
thermostat.
Start up the pump again.