Install Electrical Wiring; Connect Downdraft To Power - Bosch HDD80050UC Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION

Install electrical wiring

CAUTION: Installation work and electrical wiring must
be done by qualifi ed person(s) in accordance with all
applicable codes and standards, including fi re-rated
construction.
CAUTION: Do not use an extension cord. If the
product power cord is too short, have a qualifi ed
electrician install a three slot receptacle.
1. Install a standard wiring box, with 3-pronged receptacle,
within reach of the downdraft's power cord.
2. Remove electrical panel wiring box cover. Secure
blower power cable to electrical panel wiring box with
U.L. approved strain relief.
Based on blower selected, go to the relevent
section:
A - Flex Blower Wiring
B - Remote Blower Wiring
A - Flex Blower Wiring
3. Connect fl exible blower wires to wires in electrical panel
wiring box as shown. Cap off BLUE wires (LOW 1).
4. Replace wiring box cover.
B - Remote Blower Wiring
3. The following exterior or inline blowers can be used:
DHG6023RUC - 600 cfm (17 m
DHG6015NUC - 600 cfm (17 m
120 VAC • 60 Hz • 5.0 A (max.)
NOTE: Some blowers may come with plugs or connectors,
these should be removed and the 14/4 ROMEX or Conduit
wiring should be connected in an approved junction box.
5. Connect power wires to wires in electrical panel wiring
box as shown.
6. Replace wiring box cover.

Connect Downdraft to Power

1. Plug the downdraft's power cord into the 3-pronged
receptacle. Make sure that the power cord is routed away
from the heat generated by the cooktop.
2. Check operation.
3. Remove all protective fi lm and packaging before operation.
In order to remove all protective fi lm and packaging, raise
the intake housing and remove the front panel to access
the fi lter area.
/min) Remote Blower
3
/min) Inline Blower
3
English 19