Right Or Rear; Cut Out Ductwork Opening In Cabinet - Bosch HDD80050UC Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION
C - Installation using inline or remote
blowers - with ducting through left,

right or rear

(Requires purchase of 1-7/8" x 19" (48mm x 483mm) to 6" or
8" (152mm or 203mm) round transition. 1-7/8" x 19" (48mm x
483mm) rectangular duct and connection adapters are also
available.)
1. Remove only one RECTANGULAR DISCHARGE COVER.
DUCTING OUT RIGHT SIDE OF
HOUSING SHOWN.
2. Use nuts to connect 1-7/8" x 19" (48mm x 483mm)
rectangular ductwork connection adapter or 1-7/8" x 19"
(48mm x 483mm) to 6" or 8" (152mm or 203mm) round
transition to housing when installing ductwork.
English 16
RECTANGULAR
DISCHARGE COVERS
This
Front Panel
remains
in place.

Cut out ductwork opening in cabinet

1. Measure and mark where to cut the ductwork opening
in the cabinet based on the ducting option selected.
Use the dimensions in the illustration below to help plan
how and where to provide duct access through your
cabinet.
Hole in Cabinet Floor
Dimension A
Using Flex Blower (Model DHG602DUC) &
8" (203mm) round duct straight
down through cabinet fl oor.
(1½" /38mm left of installation center line)
7¾ inches (197mm)
2. Set downdraft into cabinet/countertop opening as far back
as possible and make sure it is level.
Measurements
in inches (mm).

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hdd86050uc

Table des Matières