BFT DEIMOS BT Instructions D'utilisation page 17

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Logic
Default
De nition
OFF
Photocell test
Safety edge
OFF
testing
ON
Fault Phot
Gate open light
OFF
or 2nd radio
channel
OFF
Pre-alarm
OFF
Deadman
START - CLOSE
OFF
setting
OFF
Fixed code
Remote control
ON
programming
OFF
Master/slave
OFF
ICE
15.3 TABLE C: RADIO MENU
Description
Add Start Key
associates the desired key with the Start command.
Add 2ch Key
associates the desired key with the 2nd radio channel command.
Read
Checks a key of a receiver and, if memorized, returns the position of the remote control in the memory (from 01 to 63) and number of the key
(T1-T2-T3 or T4).
Erase List
WARNING! Erases all memorized remote controls from the receiver's memory.
Read receiver code
Displays receiver code required for cloning remote controls.
ON = Enables remote programming of cards via a previously memorized W LINK transmitter. It remains enabled for 3 minutes from the time
the W LINK remote control is last pressed.
OFF= W LINK programming disabled.
INSTALLATION MANUAL
Cross out
setting
Description
used
ON
Switches photocell testing on
Switches photocell testing o
OFF
If disabled (OFF), it inhibits the photocell testing function, enabling connection of devices not
equipped with supplementary test contacts.
ON
Switches safety edge testing on.
Switches safety edge testing o
OFF
If disabled (OFF), it inhibits the safety edge testing function, enabling connection of devices not
equipped with supplementary test contacts.
The fault input is associated with the photocell test circuit,
ON
up to 4 pairs of tested photocells and one tested safety edge can be connected (Fig. V)
The fault input is associated with the safety edge test circuit,
OFF
up to 4 tested safety edges and one pair of tested photocells can be connected (Fig. V).
The output between terminals 14-15 is set as Gate open light:
ON
in this case, the 2nd radio channel controls pedestrian opening.
OFF
The output between terminals 14-15 is set as 2nd radio channel.
ON
The ashing light comes on approx. 3 seconds before the motors start.
OFF
The ashing light comes on at the same time as the motors start.
Deadman mode: operation continues as long as the control key is held down.
ON
(OPEN terminal 21-26, CLOSE terminal 21-22).
OFF
Pulse operation, according to 3- or 4-step logic.
ON
Input between terminals 21-22 works as CLOSE.
OFF
Input between terminals 21-22 works as START.
ON
Receiver is con gured for operation in xed-code mode.
OFF
Receiver is con gured for operation in rolling-code mode.
Enables wireless memorizing of transmitters:
1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter that has already
been memorized in standard mode via the radio menu.
2- Press within 10 secs. the hidden key (P1) and normal key (T1-T2-T3-T4) of a transmitter to be
ON
memorized.
The receiver exits programming mode after 10 secs.: you can use this time to enter other new tran-
smitters.
This mode does not require access to the control panel.
Disables wireless memorizing of transmitters.
OFF
Transmitters are memorized only using the relevant Radio menu.
Control panel is set up as the Master unit in a centralized serial connection system.
ON
WARNING: the control panel set as the master must be the rst in the series.
OFF
Control panel is set up as a Slave unit in a centralized serial connection system.
The controller automatically adjusts the Amperostop safety trip threshold at each start up. This featu-
re is useful when dealing with installations running at low temperatures.
ON
WARNING: once this feature has been activated, you will need to perform an autoset opening
and closing cycle.
OFF
The Amperostop safety trip threshold stays at the same set value.
17
DEIMOS BT-MA -

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Qsc-d maDeimos bt + qsc d ma

Table des Matières