14.1 TESTED DEVICES FIG.V
14.2 NON TESTED DEVICES FIG.H
15 CALLING UP MENUS: FIG. 1
15.1) PARAMETERS MENU
15.2) LOGIC MENU
LOGIC TABLE "B"
15.3) RADIO MENU
RADIO TABLE "C"
-
IMPORTANT NOTE: THE FIRST TRANSMITTER MEMORIZED MUST BE
IDENTIFIED BY ATTACHING THE KEY LABEL (MASTER).
In the event of manual programming, the rst transmitter assigns the RECEIVER'S
KEY CODE: this code is required to subsequently clone the radio transmitters.
The Clonix built-in on-board receiver also has a number of important advanced
features:
To use these advanced features, refer to the universal handheld programmer's
instructions and to the general receiver programming guide.
15.4 LANGUAGE MENU
Used to set the programmer's language on the display.
15.1 TABLE A: PARAMETERS MENU
Parameter
min.
max.
0 sec.
120 sec.
1%
99%
1%
99%
1%
99%
1%
99%
1 sec.
2 min.
1 sec.
2 min.
0
3
0
128
15.2 TABLE B: LOGIC MENU
Logic
Default
De nition
Automatic
OFF
Closing Time
OFF
3 step
OFF
Block Pulses
Photocells
OFF
during opening
16 -
DEIMOS BT-MA
INSTALLATION MANUAL
PARAMETERS TABLE "A"
default
personal
De nition
10
Automatic Closing Time
80
Opening motor torque
80
Closing motor torque
Opening motor torque
25
during slow-down
Closing motor torque
25
during slow-down
25
Fast Time during Opening
25
Fast Time during Closing
Slow-down speed
0
0
Zone
Cross out
setting
Description
used
ON
Switches automatic closing on.
OFF
Switches automatic closing o .
Switches to 3-step logic. A start pulse has the following e ects:
door closed: opens
ON
during opening: stops and switches on TCA (if con gured).
door open: closes
during closing: stops and opens again
Switches to 4-step logic. A start pulse has the following e ects:
door closed: opens
during opening: stops and switches on TCA (if con gured)
OFF
door open: closes
during closing: stops and does not switch on tca (stop)
after stop: opens
ON
The start pulse has no e ect during opening.
OFF
The start pulse has e ect during opening or closing.
When beam is broken, operation of the photocell is switched o during opening. During closing,
ON
movement is reversed immediately.
When beam is broken, photocells are active during both opening and closing. When beam is broken
OFF
during closing, movement is reversed only once the photocell is cleared.
15.5 DEFAULT MENU
Restores the controller's DEFAULT factory settings. Following this reset, you will
need to run the AUTOSET function again.
15.6 AUTOSET MENU
Used for automatic setting of motor torque and fast time during opening and
closing.
Before running the AUTOSET function, adjust slow-down speed (Fig. J).
WARNING! The AUTOSET operation must be performed starting from the
closing limit switch position. If you attempt to run the AUTOSET function
in any other position, the following error message will appear: "
operation will not be performed.
WARNING!! The AUTOSET operation must be performed only once you have
checked that the leaf is moving accurately (opening/closing) and that the
limit switches are tripping correctly.
WARNING: if slow-down speed is edited after the AUTOSET operation,
the AUTOSET function will need to be run again.
During this stage, it is important to avoid breaking the photocells' beams and not
to use the START, STOP, PED, CLOS and OPEN commands or the display.
WARNING! While the AUTOSET function is running, the obstacle detection
function is not active. Consequently, the installer must monitor the auto-
mated system's movements and keep people and property out of range of the
automated system.
When using bu er batteries, the AUTOSET function must be run with the control
panel running o mains power.
Description
Pause time before automatic closing.
Sets motor's operating force during opening at normal speed.
Sets motor's operating force during closing at normal speed.
Sets motor's operating force during opening at slowed speed.
Sets motor's operating force during closing at slowed speed.
Length of normal speed stage during opening.
Length of normal speed stage during closing.
Selects slow-down speed.
0=no slow-down
1=faster slow-down
2=medium slow-down
3=slower slow-down
Serial connection address.
Set the Zone number in the range 0 to 127. The zone number
allows you to create groups of automated devices, each of which
answers to the Zone Master. Each zone can have only one Master.
The Master of zone 0 also controls the Masters and Slaves of the
other zones.
Zone 128: Opposite Sliding Leaves Fig. U .
FIG. J1
" and the