Miller CST-8 Pack Rack Manuel Du Propriétaire page 24

Table des Matières
Input Votage
Amperage Input At
(3-Phase)
Rated Load Output,
50/60 Hz
220 VAC
230 VAC
400 VAC
440 VAC
460 VAC
575 VAC
* Full 280 amperes output from power source may cause rack line fuses to blow. Reduce output to 235 amperes.
** Full 280 amperes output from power source may cause rack line fuses to blow. Reduce output to 245 amperes.
{ Rack is supplied with 25 ampere fuses. No fuse kit is available.
OM-232 133 Page 20
Table 5-1. Fuse Size Requirements
Recommended Line
Fuse Size (Amps)
34.2
33.5
19.7
18.1
17.4
14.3
Individual Fuse Part
30*
199 795
30**
199 795
25
220 513
25
220 513
25
220 513
20
212 541
Bussman Fuse Part No.
No.
KTK-R-30
KTK-R-30
KTK-R-25
KTK-R-25
KTK-R-25
KTK-R-20
Table des Matières