lights

This fault may be caused by:
1. Foot switch released too early
The crimp die opens immediately to the initial position when the foot switch is released too early.
Press
.
goes out.
Repeat crimping.
2. Wrong cross section chosen.
When inserting a too large crimp contact or other unsuitable objects the crimping process is
aborted due to overloading and the crimp die opens immediately to the initial position.
Press
.
goes out.
Repeat crimping with the right cross section according to the company supplementary sheet.
3. Incorrectly set force range
If the resistance reached in the crimping process exceeds the range set on the force range
adjusting slide, the crimp die opens immediately to the initial position.
Push the force range adjusting slide up one step.
Press
.
goes out.
Repeat the crimping process until the optimum force range is set.