• Repeat the process to set the minutes for the alarm time.
• If no entry is made for 20 seconds, setup mode automatically
exits.
• To select and activate or deactivate the appropriate alarm, press
the ALARM button (20) repeatedly to select A1 or A2.
• Press the – button (23) to activate the selected alarm (A1 or
A2). The active alarm is displayed with the
symbol (9).
• When the alarm is triggered, the
begins to ash and an alarm sounds.
• Press any button (except SNOOZE/LIGHT sensor (26)) to stop
the alarm. Otherwise, it will stop automatically after 2 minutes.
Note – Snooze function
• While the alarm signal is sounding, press the SNOOZE/LIGHT
sensor (26) to activate the snooze function. Zz (11) will begin
to ash on the display. The alarm signal will stop for 5 minutes,
after which it will sound again.
• Press any button (except the SNOOZE/LIGHT sensor [26]) to
stop the snooze function and the alarm.

6.3. Temperature trend

Note – Temperature trend
The temperature trend display is not available during the rst few
hours of operation because it requires data that is collected during
operation.
• The weather station indicates a trend as to how the values for
the outdoor temperature (18) and room temperature (15) are
likely to develop over the next few hours.
Display
6.4. Maximum and minimum temperature and humidity
values
• The base station automatically stores the maximum and
minimum outdoor/indoor temperature values.
• Repeatedly press the + button (22) to switch between the
current temperature, maximum temperature (MAX) and
minimum temperature (MIN).
• Press and hold the + button (22) for approx. 3 seconds to reset
the stored maximum and minimum values.

6.5. Backlight

Press the SNOOZE/LIGHT sensor (26) to activate the backlight.
7. Care and Maintenance
Only clean this product with a slightly damp, lint-free cloth and do
not use aggressive cleaning agents. Make sure that water does not
get into the product.
or
alarm
2
1
active alarm symbol (9)
Trend
Increasing
Constant
Decreasing
8. Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no
warranty for damage resulting from improper installation/mounting,
improper use of the product or from failure to observe the operating
instructions and/or safety notes.
9. Technical Data
Base station
4,5 V
Power supply
3 x AA batteries
Measuring range
0°C – +50°C / 32°F
Temperature (°C)
– +122°F
Humidity
20% – 90%
Measurement
increments
0,1°C/ 0,2°F
Temperature
1%
Humidity
DCF radio-controlled
Yes
clock
Thermometer
Yes
Yes / 2 alarms (dual
Alarm function
alarm)
Max. number of
outdoor sensors
Range
10. Declaration of Conformity
Hereby, Hama GmbH & Co KG declares that the radio
equipment type [00186308, 00136256] is in
compliance with Directive 2014/53/EU. The full text of
the EU declaration of conformity is available at the following
internet address:
www.hama.com -> 00186308, 00136256 -> Downloads.
Frequency band(s)
Maximum radio-frequency
power transmitted
Outdoor sensor
3,0 V
2 x AAA batteries
For use in outdoor
temperatures
under 0°C/ 32°F,
we recommend
using AAA lithium
batteries for the
outdoor sensors.
-20°C – +60°C /
-40°F – +140°F
20% – 90%
0,1°C/ 0,2°F
1%
No
Yes
No
3
50 m
433 MHz
0,006 mW
5