Step 4: Power supply
 Insert the batteries into the bracket, ensuring the polarity is correct.
Step 5: Program detector into alarm panel or receiver component
The following describes direct programming on the Secvest alarm panel
FUAA50000. For web-based programming and programming to other receivers,
Note
please read the relevant chapter in the instructions about these components.
 If this has not been done already, switch the alarm panel on.
 Select:
Installer mode -> Components -> Detector -> Wireless zones -> Add/Remove detector
 Choose a free wireless zone. The message 'Activate the tamper contact of the detector' is
displayed.
 Flick the tampering switch.
The detector will then send a pairing signal to the alarm panel. The alarm panel will recog-
nise the detector.
 Once the pairing signal has been received by the wireless alarm system, it will emit two
beeps. The message 'Detector was programmed to: zone 2xy' and the incoming signal
strength are displayed.
 Confirm the successfully completed pairing on the control panel.
Step 6: Test the system
 Test the system fully.
Signal strength
Installer mode > Test > Signal strengths > Detector
After selecting the signal strengths for all detectors is displayed on the alarm panel. For more de-
tails, please refer to the relevant instructions for the alarm panel or wireless extension.
Walk test
Installer mode > Test > Walk test
After making the selection, you can choose whether to test all detectors in the system, in a parti-
tion of the system, or individual detectors. For more details, please refer to the relevant instructions
for the alarm panel or wireless extension.
Installation