16. Chromatherapy Light Operation
NOTE: These directions pertain to the use of the mounted control switch only. For more information, see
the "Using the Remote Control" section.
If the chromatherapy lights are turned off, press the button on the chromatherapy control switch
(located next to the pump control switch). The chromatherapy lights will begin to cycle through
each of the colors (sweep mode).
When the chromatherapy lights are in sweep mode, you can lock in one color light by pressing the
chromatherapy control switch.
When an individual color is locked in, press the chromatherapy control switch to turn the
chromatherapy lights off.
17. Troubleshooting Procedures
For warranty service, contact your dealer or wholesale distributor. This Troubleshooting Guide is for general
aid only. Contact a Kohler Authorized Service Representative or a qualified electrician to correct all electrical
problems. For warranty service, contact your dealer or wholesale distributor.
Symptoms
Green light in "On/Off"
1.
control switch flashes
before the bathing well is
full of water.
2.
Product does not start.
3. Water does not cascade
evenly over the entire
bathing well rim.
4. Unit stops automatically
before 18 minutes.
Kohler Co.
Probable Causes
A. Spout fills directly into overflow
channel.
B. One or both butterfly valves do
not work.
C. Control does not work.
A. No power to unit.
B. Water does not cover the overflow
channel sensors.
C. "On/Off" control switch does not
light up or flash when the unit is
running or filled as required.
D. Pump/motor does not work.
E. Control does not work.
A. Unit is not level.
B. Bathing well ports are blocked.
C. Metal suction screen is blocked.
A. GFCI/ELCB trips.
17
Recommended Action
A. Adjust/reinstall the spout to fill
directly into the bathing well.
Refer to the installer/dealer.
B. Check the butterfly valve wiring
or replace the butterfly valves.
Refer to the installer/dealer.
C. Check the wiring or replace the
control. Refer to the
installer/dealer.
A. Turn on the power to the unit, or
correct the source of the power
loss. Refer to the installer/dealer.
B. Fill the bathing well until water
flows over the bathing well rim,
into the overflow channel, and
covers the overflow channel
sensors. Suggested fill level is to
the drain overflow.
C. Check the wiring or replace the
"On/Off" control switch. Refer to
the installer/dealer.
D. Rebuild or replace the
pump/motor. Refer to the
installer/dealer.
E. Check the wiring or replace the
control. Refer to the
installer/dealer.
A. Level the unit by using the
wrench provided to turn the
adjustable feet up or down as
needed.
B. Remove blockage.
C. Clean the metal suction screen.
A. Identify the source of the fault
and correct. Refer to the
installer/dealer.
1054216-2-B