• Do not place the appliance near a heat source. Do not subject the power
cord to direct heat (such as a heated hotplate, open flames, hot iron sole
plates or heaters for example). Protect power cords from oil.
• See to it that the appliance is properly positioned to ensure a high stabil-
ity during its operation and make sure that no one can trip over the power
cord.
• The appliance is not splash-proof.
• For indoor use only.
• Do not store the appliance outdoors.
• Store the appliance in a dry place inaccessible to children (pack the ap-
pliance).
• If the power cord is damaged, it must be replaced by the manufacturer
or a repair shop authorized by the manufacturer or by similarly qualified
persons in order to avoid a hazard.
• Unplug the appliance before filling and cleaning.
Setting up / operation
1. Place Oskar little on a flat surface in the desired area. Plug the mains ca-
ble (3) into a electric socket. Use the filling opening (9) to fill the lower part
(2) with water up to the maximum mark (12), either at a water tap or with
a watering can. When you have filled the lower part at the tap, carefully
fit the upper part (1) to the lower part (2).
2. Start the appliance by pressing the on/off switch (5). The blue LED should
then light up. If a red pilot lamp (8 and 12) lights up however, this indicates
either lack of water in the appliance or failure to seat the upper part cor-
rectly on the lower part.
3. By pressing the speed level selector button (6) you can change the humid-
ity output (a blue lamp for normal evaporation, two blue lamps for high
evaporation).
4. If you find the lamps too bright (in a bedroom for example), you may reduce
the light intensity by pressing the night mode key (7). You can choose
between three different modes:
• Normal mode (default mode)
• Dimmed mode (push once)
• Lights-out mode (push twice)
• By pushing the dimmer button once more, you can go back into normal
mode.
If there is no water in the appliance, the red LEDs (8 and 12) light up in all
modes (normal and night mode). The red light can not be dimmed.
5. You can use the Oskar little air humidifier to distribute fragrances in the
room. Please be as economical as possible in the use of fragrances, be-
cause excessive quantities may lead to malfunctions and damage to the
appliance. To use fragrances, remove the fragrance container (10) from
the filling opening (9). Place no more than 2–3 drops of fragrance in the
container and replace it in the space provided in the filling opening. If you
wish to change the fragrance, you can wash out the fragrance container
and fleece under running water.
6. If you wish to top up with water during operation, you can open the filling
opening (9) by pressing on it (Push to open). You can then refill the appli-
ance using a water can or water bottle without having to switch it off.
PLEASE NOTE: If you are operating the appliance with fragrances, remove
the fragrance container before refilling to prevent water getting into it.
Should this nevertheless occur, it will be necessary to remove the water
container (2) and rinse it. Fragrances should not be permitted to enter the
water tank, since they might destroy the plastic.
Important information
Humidification with an evaporator takes time. This means that it usually
takes more than 2–3 hours to reach the desired humidity. If you operate the
humidifier in a very dry environment we recommend to operate it on speed
level 2 to reach a maximum amount of humidity in a short time.
Cleaning and cassette replacement
Prior to any maintenance work and after each use, switch off the appliance
and withdraw the mains cable from the socket.
Never immerse in water (risk of short circuit).
• External surfaces should only be wiped off with a damp cloth and then
dried well.
• Every 2 weeks: To clean the inside, remove the filter cassette and descale
the lower part if necessary. After descaling, thoroughly rinse the lower
part and then dry it before putting the air humidifier into operation again.
• For hygienic and optimum operation of the air humidifier, the filter cas-
sette should be replaced at least every two months. If the filter cassette
remains in use for longer than this, on the one hand the humidity output
may decline severely and on the other, the anti-bacterial action of the
cassette can no longer be guaranteed. The filter cassette can be obtained
from the dealer where you purchased your Oskar little.
Ionic Silver Cube ™
The Ionic Silver Cube (13) prevents the growth of germs and bacteria in the
humidifier due to the continuous release of silver ions. The use of the Ionic
Silver Cube leads to a hygienic room climate. The lifetime of the Ionic Silver
Cube is around one year. We therefore recommend that you replace the Ionic
Silver Cube at the beginning of every humidifying season. The Ionic Silver
Cube starts working as soon as it comes into contact with water, and also
works when the unit is switched off.
Repairs
• Repairs to electrical appliances must only be carried out by a qualified
electrical technician. If improper repairs are carried out, the warranty
lapses and all liability is refused.
• Never operate the appliance if the adaptor or plug is damaged, after it has
malfunctioned, if it has been dropped or has been damaged in any other
way (cracks/breaks in the casing).
• Do not push any object into the appliance.
• If the appliance is beyond repair, make it unusable immediately by cutting
through the cable and hand it in at the collection point provided for the
purpose.
Disposal
The European directive 2012 / 19 / CE on Waste Electrical and Electronic
Equipment (WEEE), requires that old household electrical appliances must

Publicité