3.5.3 RLS RC room air control
(EnOcean radio control)
For information about the RLS RC
i
control,  separate Mounting
instructions.
● The room air control RLS RC is a radio
control for the manual operation of master
and slave devices. Two programs, P1/P2,
with different combinations of performance
levels, are available for operation. The
appropriate program for the application,
(P1 for small / P2 for large living units,
 table in Chapter 10, Operation), is
defined during commissioning.
● The RLS RC display shows:
● System level 0 / Off: No bar
● System level 1: 2 bars
● System level 2: 4 bars
● System level 3: 6 bars
● The display also shows time and
temperature.
● Vacation mode is fitted with interval
operation. The switch between on and off
is done on a 30 minute cycle for all fans
(humidity protection). Radio commands
from further radio network devices are
ignored until vacation mode is switched off.
● Service menu: For system settings.
4. Environmental conditions and
operating limits
● Maximum permitted temperature of the air
medium: + 40 °C
● The units have resistance to interference in
line with EN 55014-2 (depending on pulse
form and energy factor 1000 to 4000 V).
These values can be exceeded when
operating with fluorescent tubes. In this
case, additional interference suppression
measures (L, C components or RC
module, protection diodes, varistors) are
required.
● Regulations for operation with
fireplaces
Sufficient supply air intake must be
ensured during operation with air-ventilated
fireplaces. The maximum permitted
pressure difference per living unit is 4 Pa.
The fan may only be installed in rooms with
air-ventilated fireplaces if:
● the evaluation criteria drawn up by the
responsible, regional master chimney
sweep are met,
● a parallel operation of air-ventilated
fireplaces for liquid or gaseous fuels and
the air-extracting equipment can be
prevented, or
● the extraction of exhaust gas from the
air-ventilated fireplaces is monitored by
special safety equipment. The ventila-
tion unit or the fireplaces must be
switched off if the equipment is
triggered.

5. Technical data

For technical data,  rating plate. For dimen-
sions and characteristic curves:  catalogue
or Internet (maico-ventilatoren.com).
Rated voltage
Power frequency
Protection type
● Fan
● Switch, control
Radio components:
Frequency range
(in acc. to EN 300220-1)
Operating distances in the
building are dependant on the
building materials used
● Room air control
RLS RC  Fan
● Radio switch DS RC  Fan
● Fan  Fan
● Signal amplifier  Fan
EN
230 V
50 Hz
IP X5
IP 00
868.35 MHz
up to:
30 m
30 m
30 m
40 m
21