Télécharger Imprimer la page

Vortice AIRLINK 30 Livret D'instructions page 39

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 52
ENGLISH
control (see fig. 30).
Note 2: The Wi-Fi module allows to balance the air flow rates of intake and extracted air, provided that the
total number of installed units is equal to an even number. For example, 4 units can be connected
to the Wi-Fi network, setting two units as "even" and two units as "odd". Air flow balancing will
not occur if an odd number of units is installed.
Note 3: To see how to set the device as an even or an odd unit, refer to the section "parameter
programming sequences".
Note 4: The backlighting of the keys on the device remains active for one minute from the last press of
any key.
Note 5:The backlighting of the keys on the remote control of HCS versions remains active for 15 seconds
from the last press of any key.
C: FUNCTION KEY to activate or deactivate the 3 different AUTO functions available and activate or deactivate
the stand-by mode.
To activate or deactivate the stand-by mode:
If the device is switched on and the FUNCTION key is pressed (stand-by / on-off function), the fan stops and the
LEDs of the SPEED column turn off. If the appliance is off and you press the FUNCTION button, the appliance
starts at the speed and mode previously set.
The available functions are:
• Auto night (only for HCS models)
The ambient light sensor detects the presence or absence of ambient light and, depending on whether the
measurement is higher or lower than the threshold value set via SW (fixed value that cannot be changed
by the user) it allows or prevents both the switch to a speed higher than the minimum both the transition
to boost speed via remote input or HR% sensor.
Therefore, at night when the presence of daylight is not detected, the appliance switches to minimum
speed preventing the switch to a speed higher than the minimum one.
When the presence of daylight is detected again, the appliance returns to operate at the previously set
speed, and it is allowed the switch to higher speeds or boost via remote input or HR% sensor.
• Auto HR%
In case of presence of humidity beyond the alarm threshold (60%, 75% or 90% - the default value is
75%), it is automatically selected the extraction mode at maximum speed.
• Auto comfort
In heat recovery mode, the period that determines the inversion of rotation of the fans is fixed based on
the temperature of the air introduced into the room: if too cold, the cycle time is reduced.
To enable a function (fig. 27):
1) press the FUNCTION button for more than 2 seconds.
2) press the SPEED button to select one of the three LEDs
(LED 1, LED 2, LED 3) corresponding to the
AUTONIGHT / AUTO HR% / AUTO COMFORT
functions.
3) press the MODE button to enable the function -> the
chosen LED in the mode column blinks.
4) to SAVE the settings, press the FUNCTION button for
more than 2 seconds.
All SPEED LEDs blink 4 TIMES to indicate correct
storage.
5) to CANCEL and exit the setting procedure, press the
FUNCTION key once. All SPEED LEDs blink ONLY
ONCE WITHOUT SAVING any changes made.
6) to CHECK which function is assigned to the appliance,
press the FUNCTION button for more than 2 seconds:
the LED corresponding to the set function blinks for
about 20 seconds, then all the speed LEDs flash and
the device returns to standard display.
Note: The user can enable all the three functions
simultaneously.
27
27
LED
EXTRACTION /AUTO COMFORT
LED
INTAKE /AUTO HR%
LED
RECOVERY
/AUTO NIGHT
FUNCTION
BUTTON
1
LED 5
LED 4
LED 3
LED 2
LED 1
MODE
SPEED
BUTTON
BUTTON
3
2
39

Publicité

loading

Ce manuel est également adapté pour:

Airlink 30 hcsAirlink 40Airlink 40 hcs