Télécharger Imprimer la page

Nilfisk CTS40 Manuel D'instructions page 32

Masquer les pouces Voir aussi pour CTS40:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

CTS22 - CTS40 - CTT40
Controls and indicators
1.
Vacuum unit start/stop switch
Use the button to start/stop the first motor. If the indicator
is lit, the main motor is ON.
2.
Vacuum gauge
3.
Manual filter shaker lever
Inspections prior to starting
1.
Vacuum inlet
Before starting, check that:
The filters are installed.
The closing band is properly tightened.
The vacuum hose and tools have been correctly fitted into
the vacuum inlet (1).
In case of liquid application, the liquid mechanical stop is
properly installed inside the liquid container:
The bag or safety container is installed, if applicable.
Do not use the device if the filters are faulty.
Starting and stopping
Before starting the machine, lock the castor brakes
Turn the switch (1) to "I" position to start.
Turn the switch (1) to "0" position to turn the vacuum
cleaner off.
Check the machine operation.
If the machine does not vacuum any air, the rotation
direction is not correct; remove the plug from the socket
I
and turn the selector inside the plug to perform the correct
phase connection.
GB
Machines equipped with system for vacuuming
liquids
F
When the container is full, the liquid mechanical stop turns
off the vacuuming; the vacuum unit remains on.
D
Do not let the vacuum unit running, after the liquid stop
has been activated. Turn it off with the relevant switch.
E
Machines equipped with an electrical control panel
equipped with phase sequence control relay
Turn the main switch to "I" to electrically power the
machine.
Press the start button to start the machine.
Press the stop button to stop the machine.
Turn the switch to "0" to turn off the machine.
C313
Figure 5
Figure 6
CAUTION!
Figure 5
CAUTION!
[ NOTE ]
If the machine does not vacuum any air, the motor rotation
direction is wrong and reverse phase indicator turns on.
Disconnect the plug from the power socket and turn the
phase inverter.
Machines equipped with an electrical system preset
for start from vacuum inlets
Turn the main switch to "I" to electrically power the
machine.
Press the start button to start the machine.
If the machine is equipped with vacuum inlet sensor, vacuuming
will start automatically, after performing the above procedure,
when the first inlet will be opened by the operator.
The machine will stop two minutes after the last inlet is closed
by the operator. To immediately stop the machine press the
stop button (6).
Too frequent starts of the machine can damage the
motor; it is advisable not to modify the tripping time of
the sensor located on the vacuum inlets.
List of control symbols and indicator lights
on the electrical panel
10
[ NOTE ]
CAUTION!
Agitator-mixer
Hopper Load
Container/outlet/bag full
Container/outlet/bag
Inlets too simultaneous
Clogged absolute filter
Clogged primary filter
Low compressed air pressure
Manual-Automatic

Publicité

loading

Ce manuel est également adapté pour:

Cts22Ctt40