V2 AYROS 400D-230V Mode D'emploi page 49

Operateur electromecanique 230v irreversible a cremaillere pour portails coulissants jusqu'a 1200 kg de poids

Publicité

Les langues disponibles

Les langues disponibles

PARAMETER
VALUE
Strt
StAn
no
AP.Ch
PrES
oroL
StoP
no
ProS
invE
Fot1
no
AP.Ch
Fot2
CFCh
Ch
no
Ft.tE
no
Si
DESCRIPTION
Activation inputs function
This menu allows selecting input operation modes (see chapter 4.4)
Standard mode
Start inputs from terminal board are disabled.
Radio inputs operate in standard mode
Open/Close command
Manned operation
Timer mode
STOP INPUT
The input STOP is not available (ignored by the control unit)
The input STOP stops the gate: pressing the command START the gate
continues the motion
The command STOP stops the gate: at the next START the gate starts
moving in the opposite direction
Photocell 1 input
This menu allows enabling the input for type 1 photocells, that is to say,
photocells active both during the opening and closing phase
Input disabled (ignored by the control unit)
Input enabled
Photocell 2 input
This menu allows enabling the input for type 2 photocells, that is to say,
photocells non active during the opening phase
Input enabled even at standstill gate too: the opening movement does not
start if photocell is interrupte
Input enabled for the closing phase only
WARNING: if you select this option, you must disable photocell test
Input disabled (ignored by the control unit)
Test of the photocells
Function deactivated
In order to achieve a safer operation for the user, the unit performs a
photocells operational test, before a normal working cycle.
If no operational faults are found, the gate starts moving.
Otherwise, it will stand still and the flashing light will stay onfor 5 sec.
The whole test cycle lasts less than one second.
StAn
- 47 -
DEFAULT
MEMO
StAn
no
no
CFCh
no