Télécharger Imprimer la page

V2 AYROS 400D-230V Mode D'emploi page 44

Operateur electromecanique 230v irreversible a cremaillere pour portails coulissants jusqu'a 1200 kg de poids

Publicité

Les langues disponibles

Les langues disponibles

9 - INSTALLATION MENÙ (SEt)
This menu allows you to perform the movements of the gate
needed during installation.
The automatic learning procedure enables to save run limits based
on data collected by the encoder.
The manual handling procedure allows to control the gate in hold
to run mode in special cases such as during installation /
maintenance or a malfunction of the photocells or edges.
m
ATTENTION: before proceeding, make sure to position
the mechanical stops and the limit sensors correctly.
1. Press and hold the OK key until the display shows
2. Release the OK key: the display shows
key if it is desired to exit this menu)
h
i
3. Use the keys
and
to select the menu
APPr
manual handling or
procedure of the run limits
4. Press OK to start the selected procedure
9.1 - AUTOMATIC LEARNING OF THE RUN
LIMITS
m
CAUTION: to perform the self-learning procedure it
is necessary to disable the ADI interface by means of the
i.Adi
menu
. If some safeties are controlled by means of the
ADI module, they will not be active during the self-learning
NOTE: during the self-learning the slowdown in the limit
switch area is not active.
To store the precise position of the range limit it is
recommended to activate the slow speed near to the limit.
The position at which the slow speed is activated is stored
as the starting point for slowing down.
5. The display shows the control panel and the automatic learning
procedure of the run limits starts.
5.1 If the gate is not at the closed limit, the motor will
activate to close at the slow speed until it reaches the
range limit.
5.2 Gate opening is activated until the opening limit switch is
reached.
NOTE: To slow down the motor press the control unit
i
button
or activate the START P. command (wired or
wireless) when the gate comes close to the range limit.
5.3 Gate closing is activated until the closing limit switch is
reached.
NOTE: To slow down the motor press the control unit
i
button
or activate the START P. command (wired or
wireless) when the gate comes close to the range limit.
6. At the end of the automatic learning procedure, the control
unit automatically exits this menu and returns to normal
operation.
-SEt
ESC
(only press the OK
Mov
to activate
to start the automatic learning
9.2 - MANUAL HANDLING
m
WARNING: when this procedure is activated the
safeties are not active.
MAn
5. The display shows
h
6. Press and hold the
close the gate
7. Release the button to stop the gate
8. To exit this menu, press OK
NOTE: If the motor is inactive for more than one minute
the procedure terminates automatically.
-SEt
- 42 -
i
key to open the gate or the
ESC
APPr
Mov
MAn
button to

Publicité

loading

Ce manuel est également adapté pour:

Ayros 800-230vAyros 1200-230v