1. Replace oil with corrosion inhibitor oil
(viscosity SAE 30). See Chap. 2.6.7.
2. Allow the compressor to warm up, switch
it off, disconnect the power supply.
3. Drain the condensate, depressurise the
compressor.
4. Prior to returning to operation, replace
corrosion inhibiting oil with compressor
oil.
Store the compressor in a dust-free and dry
area where it is not exposed to high tem-
perature fluctuations.
2.8 Troubleshooting
Problem
A Protective motor
switch interrupts
power supply
B Pressure
relief
does not function
C Compressor does
not start when
switched on.
D Compressor
starts up briefly /
buzzes and then
switches
off
automatically
E Compressor runs
continuously
Cause
In case of malfunctions (e.g.
overheating;
low
extension cable too long or
with incorrect cross-section),
the protective motor switch is
tripped.
Power failure / undervoltage in
mains
with
switched on
Vessel pressure is higher than
switch-on pressure.
Power supply faulty.
Protective motor switch inter-
rupts power supply.
Pressure switch defective
Mains connection cable longer
than permitted or the cross
section is too small
Intake filter badly contami-
nated
Air consumption of compressed
air tools is too high
Leakage at compressor
Excessive condensate in the
tank
Compressed air line leaky
Condensate drain valve is open
or missing
2.7.2
Environment
Do not dispose of the device in
household waste! Recycle de-
vices, accessories and packaging.
Observe applicable national regu-
lations.
EU only: In accordance with European Di-
rective on waste electrical and electronic
equipment and implementation in national
law, used electric power tools must be col-
lected separately and handed in for environ-
mentally friendly recycling.
Remedy
Switch off the compressor. Wait a
voltage;
short while. Actuate the protective
motor switch is available. Switch on
the compressor.
Protective motor switch trips again:
switch off compressor. Disconnect
the power supply. Contact the ser-
vice partner
Switch off the compressor. It de-
compressor
pressurises. Switch on the com-
pressor
Relieve pressure in the vessel until
the pressure switch is activated au-
tomatically.
Have the power supply checked by
a qualified person (service partner).
See item A.
Have the pressure switch changed
by a qualified person.
Check connection cable length and
cable
Chap. 2.4.4)
Clean or replace
Check air consumption. Contact the
service partner
Locate leak, contact service partner
Drain
Chap. 2.6.5)
Check the compressed air network,
seal leak
Close or replace
CPM
cross-section
the
condensate
GB
(see
(see
II/11