off again if the rotation direction is incor-
rect.
2. Unplug the power plug.
3. Three-phase plug with phase inverter:
press it in and rotate it by 180°. (Figure
2a)
Three-phase plug without phase invert-
er: reverse the phases in the plug.
Repeat step 1.
4. If direction of rotation has not changed:
contact service partner.
2.5 Operation
 Do not overload the compressor: do not
exceed the max. number of switching cy-
cles and the ratio of operating time to
standstill!
2.5.1
Insert
Switch on the compressor at the ON/OFF
switch (item 10). The compressor starts up
2.6 Maintenance
Interval / No later
than
-- / As needed
-- / after each use
daily / commissioning
Once after 10 h / --
-- / Weekly
50 h / After 6 months
500 h / after 1 year
1,000 h / after 2 years Change oil (with synthetic oil)
2,500 h / After 5 years Change safety valve
2.6.1
Before each maintenance task
1. Swtich on the compressor at the ON/OFF
switch (item 10). Disconnect the power
supply.
2. Depressurise the compressor: using the
blow gun, blow out all pressure from the
vessel.
Tasks
Clean compressor
Clean intake filter
Clean the filter insert (water separator with filter)
Change the filter element in the water separator
Drain condensate from pressure vessel
Drain the condensate from the water separator with filter 2.6.4
Check the oil level, add oil if necessary.
Check screw connections
Check intake filter
Clean intake filter
Change oil (1st oil change mineral or synthetic oil)
Change oil (with mineral oil)
Change intake filter
Change check valve and insert
Check screw connections
Change the filter element in the water separator
and switches off automatically at maximum
pressure.
2.5.2
Adjusting the working pressure
1. Pull up the adjustment button on the
pressure reducer (fig. 3a).
2. Rotate clockwise = pressure is in-
creased. Rotate anticlockwise = pressure
is reduced.
3. Press the adjustment button down to
lock it in place.
2.5.3
After use
1. Switch off the compressor.
2. Disconnect the power supply.
3. Disconnect plug nipple of air hose from
(safety) quick-action coupling.
4. Clean compressor (Chap. 2.6.2), depres-
surise it (Chap. 2.6.1), transport to stor-
age location (Chap. 2.4.1).
 Only drain oil if the unit has been suffi-
ciently cooled.
2.6.2
Cleaning the compressor
• Clean the cooling fins on the cylinder, cyl-
inder head and aftercooler using com-
pressed air.
• Clean the fan impeller cover on the motor.
GB
CPM
See
chap.
2.6.2
2.6.9
2.6.3
2.6.12
2.6.5
2.6.6
2.6.8
2.6.9
2.6.9
2.6.7
2.6.7
2.6.9
2.6.10
2.6.8
2.6.12
2.6.7
2.6.11
II/9

Publicité

loading

Ce manuel est également adapté pour:

A 224 001