8 TECHNICAL SPECIFICATIONS
Power supply voltage U1 (50/60Hz)
*
Zmax (@PCC)
Slow blow line fuse
Communication bus
Maximum input power (kVA)
Maximum input power (kW)
Power factor PF
Efficiency (μ)
Cos
Max. input current I1max
Effective current I1eff
Duty factor (40°C)
(x=35%)
(x=60%)
(x=100%)
Duty factor (25°C)
(x=60%)
(x=100%)
Adjustment range I2
MMA open circuit voltage Uo
TIG open circuit voltage Uo
IP Protection rating
Insulation class
Manufacturing Standards
Dimensions (lxdxh)
Weight
Power supply cable
Length of power supply cable
*
This equipment complies with EN/IEC 61000-3-11.
*
This equipment does not comply with EN/IEC 61000-3-12. If it is connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the distribution network operator if necessary, that the equipment may be
connected. (Consult the "Electromagnetic fields & interferences" - " EMC equipment classification in accordance with EN/IEC 60974-10" section).
All manuals and user guides at all-guides.com
GENESIS 2000
3x400Vac ±15%
-
10A
DIGITAL
9.7kVA
6.5kW
0.7
85%
0.99
14A
8.3A
200A
170A
150A
200A
160A
3-200A
70Vdc
60Vdc
IP23S
H
EN 60974-1
EN 60974-10
410x150x330 mm
11.3 kg.
4x2.5 mm2
5 m
GENESIS 2000 RC
3x400Vac ±15%
-
10A
DIGITAL
9.7kVA
6.5kW
0.7
85%
0.99
14A
8.3A
200A
170A
150A
200A
160A
3-200A
70Vdc
60Vdc
IP23S
H
EN 60974-1
EN 60974-10
410x150x330 mm
11.3 kg.
4x2.5 mm2
5 m
29

Publicité

loading

Ce manuel est également adapté pour:

Genesis 2000 rc