P = C* Constant power
The increase in arc length causes a reduction in the
welding current (and vice versa) according to the law:
V.I = K.
Cellulose, Aluminium
*
Increasing the value of the arc force to reduce the risks
of sticking of the electrode.
40
Measurements
Permits selection of the type of measurement to be
shown on the display 4.
0 Real current
1 Real voltage
2 No measurement
Default 0
42
Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1.
43
External parameter 1
Allows the management of external parameter 1 (mini-
mum value).
44
External parameter 1
Allows the management of external parameter 1 (maxi-
mum value).
3.3.2 Alarm codes
01/02/03 Overtemperature
10
Power module alarm
11
Machine configuration not valid
20
Communication error
21
Loss of data or memory not initialised
3.4 Rear panel
1
Power supply cable
Connects the system to the mains.
2
Signal cable (CAN-BUS) input (RC)
3
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
All manuals and user guides at all-guides.com
3.5 Sockets panel
1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.
4 ACCESSORIES (Genesis 2000 RC)
4.1 General
Operation of the remote control is activated when connected
to the Selco power sources. This connection can be made also
with the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 100 remote control
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".
4.3 RC 200 remote control
The RC 200 is a remote control unit designed to manage the
display and the adjustment of all available parameters of the
power source to which it is connected.
"Consult the instruction manual".