(5) Other displays and flashing
– "CENTRALLY CONTROLLED" display –
CENTRALLY CONTROLLED
DRY COOL
DAILY
AUTO OFF
AUTO FAN
CHECK
SET TEMP.
HEAT
STAND BY
DEFROST
• Displayed when operation is controlled by central controller, etc.
Restricted operations are shown below.
· ON/OFF (including timer operation)
· Operation mode
· Set temperature
NOTE
May also be individually restricted.
– "FILTER" flashing –
DRY
COOL
DAILY
AUTO OFF
AUTO FAN
CHECK
HEAT
STAND BY
DEFROST
• Indicates that the filter needs cleaning.
Clean the filter.
• When resetting "FILTER" display
When the [FILTER] button is pressed two times successively after
cleaning the filter, the display goes off and is reset.
– "ERROR CODE" flashing –
CHECK
unit number
• When both the "ON" lamp and "ERROR CODE" flash, trouble oc-
curred in the air conditioner and the air conditioner stops.
Jot down the unit number and error code and turn off the air condi-
tioner power and consult your dealer.
(6) How to select the remote controller functions
In the remote controller function selection mode, three functions can be selected and changed. Select and change them as required.
1) Operation mode display selection mode (Automatic mode cool/heat display selection)
When the AUTO operation mode was set by remote controller, the indoor unit is judged from the room temperature and the cooling or heating
operation is performed automatically. In this case, "AUTO" "COOL" or "AUTO" "HEAT" is displayed at the remote controller. However, "AUTO" can be
displayed alone without the "COOL" or "HEAT" display.
2) Room temperature display selection mode (Room temperature display/no display selection)
Normally, the intake temperature is displayed at the remote controller, but setting can be performed so that it is not displayed.
3) Set temperature range limit mode
Ordinarily, the set temperature adjustment range can be freely set to the 65 °F to 87 °F range for cooling and dry and the 61 °F to 83 °F range for
heating. However, the lower limit temperature can be preset to an arbitrary value for cooling and dry and the upper limit temperature can be preset
to an arbitrary value for heating. If the set temperature range for cooling and dry is set to a value higher than normal and the set temperature range
for heating is set lower than normal in this way, overcooling and overheating can be prevented and energy can be saved.
NOTE
When the set temperature adjustment range was changed from the normal set temperature adjustment range by remote controller connected to a cooling/
heating simultaneous air conditioner with an AUTO mode, the AUTO mode cannot be selected with the [NODE] button.
CENTRALLY CONTROLLED
1Hr.
DRY
COOL
DAILY
AUTO
AUTO
TIMER
AUTO OFF
ON
OFF
AUTO
FAN
FAN
FAN
CLOCK
SPEED
SPEED
CHECK
SET TEMP.
REMAINDER
HEAT
VENTILATION
STAND BY
ERROR CODE
NOT AVAILABLE
2
DEFROST
SET TEMP.
3
MODE
TIMER
CLOCK→ON→OFF
FUN SPEED
AIR DIRECTION
LOUVER
VENTILATION
TIMER SET
PAR-F27MEA-US
1
1Hr.
SENSAOR
AUTO
AUTO
TIMER
INSIDE
ON
OFF
FAN
CLOCK
SPEED
REMAINDER
FILTER
CHECK MODE
VENTILATION
TEST RUN
ERROR CODE
NOT AVAILABLE
LIMIT TEMP.
1Hr.
SENSAOR
AUTO
AUTO
TIMER
INSIDE
ON
OFF
FAN
CLOCK
SPEED
SET TEMP.
REMAINDER
FILTER
CHECK MODE
VENTILATION
TEST RUN
ERROR CODE
NOT AVAILABLE
LIMIT TEMP.
ON lamp (flashed)
ERROR CORD
ON/OFF
[Remote controller function selection mode transition]
OFF window
1 ↑
↓ 1
SENSAOR
INSIDE
Remote controller function selection modes
FILTER
CHECK MODE
TEST RUN
LIMIT TEMP.
Operation mode display selection mode
ON/OFF
FILTER
Room temperature display selection mode
CHECK TEST
Set temperature adjustment range limit mode (cool/dry)
4
Set temperature adjustment range limit mode (heat)
– "Operation mode" flashing –
<When flashes continuously>
• Displayed when another indoor unit connected to the outdoor unit is
already operating in a different operation mode.
Match with the operation mode of the other indoor unit.
<When mode switched after display flashes>
• Displayed when operation mode is restricted for each season by cen-
tral controller, etc.
Use another operation mode.
NOTES
- When two or more different types of indoor unit are controlled, the clean-
ing period differs with the type of filter. When the master unit cleaning
period arrives, "FILTER" is displayed. When the filter display goes off,
the cumulative time is reset.
- "FILTER" indicates the cleaning period when the air conditioner was
used under general indoor air conditions by criteria time. Since the de-
gree of dirtiness depends on the environmental conditions, clean the
filter accordingly.
- The filter cleaning period cumulative time differs with the model.
• When only "ERROR CODE" flashes
(ON lamp remains a steady light)
The air conditioner continues to operate, but there is the possibility of
trouble occurring.
Jot down the error code and consult your dealer.
3 ↑
↓ 2
3 ↑
↓ 2
3 ↑
↓ 2
1Hr.
DRY COOL
SENSAOR
DAILY
AUTO
AUTO
TIMER
INSIDE
AUTO OFF
ON
OFF
AUTO FAN
FAN
CLOCK
SPEED
CHECK
SET TEMP.
REMAINDER
FILTER
HEAT
CHECK MODE
VENTILATION
TEST RUN
STAND BY
ERROR CODE
NOT AVAILABLE
LIMIT TEMP.
DEFROST
1Hr.
DRY
COOL
SENSAOR
SENSAOR
DAILY
AUTO
AUTO
TIMER
AUTO OFF
ON
OFF
AUTO FAN
FAN
CLOCK
SPEED
CHECK
SET TEMP.
REMAINDER
HEAT
CHECK MODE
VENTILATION
TEST RUN
STAND BY
LIMIT TEMP.
ERROR CODE
NOT AVAILABLE
DEFROST
ON/OFF
[Remote controller OFF window display]
1:Press and hold down the [CHECK] and
[MODE] buttons at the same time for 2
2
3
seconds
2:[SET TEMP. (
3:[SET TEMP. (
INSIDE
INSIDE
FILTER
FILTER
)] button
)] button
7

Publicité