CITY MULTI Control System
ME Remote Controller
Installation Manual
This manual describes installation of the ME remote controller that connects to CITY MULTI air conditioner indoor unit. Please read this manual
thoroughly and install the remote controller accordingly. For information on how to wire and install the air conditioning units, refer to the installation
manual for them.
1
Safety Precautions
G Read these Safety Precautions and perform installation work accordingly.
G The following two symbols are used to dangers that may be caused by incorrect use and their degree:
WARNING
CAUTION
G After reading this installation manual, give it and the indoor unit installation manual to the end user.
G The end user should keep this manual and the indoor unit installation manual in a place where he or she can see it at anytime. When someone moves
or repairs the PAR-F27MEA-US, make sure that this manual is forwarded to the end user.
Ask your dealer or technical representative to install the unit.
Any deficiency caused by your own installation may result in an electric shock
or fire.
Install in a place which is strong enough to withstand the weight of the
PAR-F27MEA-US.
Any lack of strength may cause the PAR-F27MEA-US to fall down, resulting
in personal injury.
Firmly connect the wiring using the specified cables. Carefully check
that the cables do not exert any force on the terminals.
Improper wiring connections may produce heat and possibly a fire.
Never modify or repair the PAR-F27MEA-US by yourself.
Any deficiency caused by your modification or repair may result in an electric
shock or fire.
Consult with your dealer about repairs.
Do not install in any place exposed to flammable gas leakage.
Flammable gases accumulated around the body of PAR-F27MEA-US may
cause an explosion.
Do not use in any special environment.
Using in any place exposed to oil (including machine oil), steam and sulfuric
gas may deteriorate the performance significantly or give damage to the com-
ponent parts.
Wire so that it does not receive any tension.
Tension may cause wire breakage, heating or fire.
Completely seal the wire lead-in port with putty etc.
Any dew, moisture, insects entering the unit may cause an electric shock or a
malfunction.
Do not wash with water.
Doing so may cause an electric shock or a malfunction.
Do not install in any place at a temperature of more than 104
°
°
less than 32
F (0
C) or exposed to direct sunlight.
Do not install in any steamy place such a bathroom or kitchen.
Avoid any place where moisture is condensed into dew. Doing so may cause
an electric shock or a malfunction.
Do not install in any place where acidic or alkaline solution or special
spray are often used.
Doing so may cause an electric shock or malfunction.
2
Confirming the Supplied Parts
Confirm that the box includes the following parts, in addition to this installation manual:
1. Remote controller (cover, body) ..................................................................................... 1
2. Remote control cord 10 m (32 ft) .................................................................................... 1
3. Cross recessed pan head screw (M4 × 30) .................................................................... 2
4. Wood screw (4.1 × 16, used for directly hooking to the wall) ......................................... 2
5. Instruction book .............................................................................................................. 1
6. Caution label (in 10 languages) ...................................................................................... 1
This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA-US.
This symbol denotes what could lead to a personal injury or damage to your property if you misuse the PAR-F27MEA-US.
WARNING
Ensure that installation work is done correctly following this installa-
tion manual.
Any deficiency caused by installation may result in an electric shock or fire.
All electrical work must be performed by a licensed technician, accord-
ing to local regulations and the instructions given in this manual.
Any lack of electric circuit or any deficiency caused by installation may result
in an electric shock or fire.
Do not move and re-install the PAR-F27MEA-US yourself.
Any deficiency caused by installation may result in an electric shock or fire.
Ask your distributor or special vendor for moving and installation.
To dispose of this product, consult your dealer.
CAUTION
Use standard wires in compliance with the current capacity.
A failure to this may result in an electric leakage, heating or fire.
Do not touch any PCB (Printed Circuit Board) with your hands or with
tools. Do not allow dust to collect on the PCB.
Doing so may cause fire or an electric shock.
Do not remove the insulation sheet on the PCB.
Doing so may cause an electric shock.
Do not touch any control button with your wet hands.
Doing so may cause an electric shock or a malfunction.
Do not press any control button using a sharp object.
Doing so may cause an electric shock or a malfunction.
Never contact the power supply with the control wiring terminals.
Doing so will certainly cause the controller to catch fire.
When installing the remote controller in a hospital or communication
°
°
F (40
C) or
facility, take ample countermeasures against noise.
Inverters, emergency power supply generators, high-frequency medical equip-
ment, and wireless communication equipment can cause the remote control-
ler to malfunction or to fail. Radiation from the remote controller may effect
communication equipment and prevent medial operations on the human body
or interfere with image transmission and cause noise.
PAR-F27MEA-US
Remote controller cover
Remote controller case
1

Publicité

loading

Sommaire des Matières pour Mitsubishi Electric PAR-F27MEA-US

  • Page 1 This symbol denotes what could lead to serious injury or death if you misuse the PAR-F27MEA-US. CAUTION This symbol denotes what could lead to a personal injury or damage to your property if you misuse the PAR-F27MEA-US. G After reading this installation manual, give it and the indoor unit installation manual to the end user.
  • Page 2 How to wire transmission line When grouping by same refrigerant system group 01 group 02 group 03 Outdoor unit Indoor unit Indoor unit Indoor unit Indoor unit TB15 TB15 TB15 TB15 Remote Master Subordiate Remote Controller Remote Remote Controller Controller Controller 1 Wiring from the remote controller •...
  • Page 3 NOTE: If you need to use a cable extension longer than 10 m (32 ft), select an electric wire that meets the following specifications: Wire specification ..CVV (2-core): 1.25 mm (16 AWG) or equivalent * CVV is a control cable which is sheathed in polyvinyl chloride with polyvinyl insulated wires inside. How To Install Extra space External size...
  • Page 4 Install the lower case on the switch box or directly on the wall. When installing directly on the wall When using the switch box Remote control cord Remote control cord Switch box for two units Cross recessed pan head screw (See 5 below) (See 5 below) Wood screw...
  • Page 5 FAN SPEED AIR DIRECTION FILTER LOUVER VENTILATION CHECK TEST PAR-F27MEA-US TIMER SET [“H0” flashing display] [OFF display] Group registration 2 2 2 2 2 Displaying “GROUP REGISTRATION”. - Press and hold down the A [FILTER] and B [Louver] buttons at the same time for two sec- onds.
  • Page 6 Stop test run by pressing the [ON/OFF] button. MODE TIMER CLOCK ON OFF FAN SPEED AIR DIRECTION FILTER LOUVER VENTILATION CHECK TEST During test run, the RUN lamp remains on. PAR-F27MEA-US TIMER SET [TEST] button Piping temperature monitoring destination button...
  • Page 7 G Après avoir lu ce manuel d’installation, veuillez le remettre à l’utilisateur avec le manuel d’installation de l’appareil intérieur. G L’utilisateur doit conserver ce manuel et le manuel d’installation de l’appareil intérieur à portée de main. Après tout déplacement ou réparation de la commande à distance PAR-F27MEA-US, assurez-vous que l’utilisateur est bien en possession de ce manuel. AVERTISSEMENT Faire installer la PAR-F27MEA-US par un concessionnaire agréé...
  • Page 8 3 Installation des câbles de transmission Pour la mise en réseau d’un même système réfrigérant Groupe 01 Groupe 02 Groupe 03 Appareil Appareil intérieur Appareil intérieur Appareil intérieur Appareil intérieur extérieur TB15 TB15 TB15 TB15 Commande Commande Commande Commande à distance à...
  • Page 9 REMARQUE: Si le réseau compte plusieurs systèmes réfrigérants, interchangez les connecteurs de sélection de l’alimentation (CN41) et (CN40) au niveau des circuits intégrés du panneau de commande de l’appareil extérieur uniquement. REMARQUE: Si vous devez utiliser une extension de câble d’une longueur supérieure à 10 m (32 ft), sélectionnez un câble électrique conforme aux spécifications suivantes: Spécification du câble……CVV (deux âmes): 1,25 mm (16 AWG) de section ou équivalent...
  • Page 10 Installez la partie inférieure sur le boîtier de distribution ou directement sur le mur. Si vous l’installez directement sur le mur Cordon de la commande à distance Si vous utilisez le boîtier de distribution (Reportez-vous à l’opération 5 ci-dessous) Cordon de la commande à distance Boîtier de distribution pour deux appareils (Reportez-vous à...
  • Page 11 AIR DIRECTION FILTER ser l’opération suivante. LOUVER VENTILATION CHECK TEST PAR-F27MEA-US TIMER SET [“H0” clignote] [Affichage éteint] Enregistrement en réseau 2 2 2 2 2 Affichage de “ENREGISTREMENT EN RÉSEAU” - Appuyez simultanément sur les touches A [FILTER] (filtre) et B [Ailette] et maintenez-les enfoncées pendant deux secondes.
  • Page 12 Arrêtez l’essai de fonctionnement en appuyant sur la touche [ON/OFF] MODE TIMER CLOCK ON OFF FAN SPEED AIR DIRECTION FILTER LOUVER VENTILATION CHECK TEST Pendant l’essai de fonctionnement, le témoin RUN (fonctionnement) reste allumé. PAR-F27MEA-US TIMER SET Touche [TEST] (essai) Touche de destination du capteur de température des tuyaux...